Description HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
Datasheet JQ1P-12V DatasheetJQ1P-12V Datasheet (PDF)

HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY VDE JQ RELAYS 20 .787 10 .394 15.6 .614 FEATURES • High electrical noise immunity • High switching capacity in a compact package • High sensitivity: 200 mW (1a), 400 mW (1c) • High surge voltage: 8,000 V between contacts and coil • UL, CSA, VDE, TÜV, SEMKO approved • Class B coil insulation type available mm inch SPECIFICATIONS Contact Standard type High capacity type Arrangement 1 Form A, 1 Form C Initial contact resistance, max. (By .

  JQ1P-12V   JQ1P-12V


Document
HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY VDE JQ RELAYS 20 .787 10 .394 15.6 .614 FEATURES • High electrical noise immunity • High switching capacity in a compact package • High sensitivity: 200 mW (1a), 400 mW (1c) • High surge voltage: 8,000 V between contacts and coil • UL, CSA, VDE, TÜV, SEMKO approved • Class B coil insulation type available mm inch SPECIFICATIONS Contact Standard type High capacity type Arrangement 1 Form A, 1 Form C Initial contact resistance, max. (By voltage drop 6 V DC 1 A) 100 mΩ Contact material Silver alloy 5 A 125 V AC 10 A 125 V AC 1a 2 A 250 V AC 5 A 250 V AC 5 A 30 V DC 5 A 30 V DC Nominal switching capacity Rating (resistive) N.O. 1c N.C. 5 A 125 V AC 2 A 250 V AC 3 A 30 V AC 2 A 125 V AC 1 A 250 V AC 1 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 3 A 125 V AC 2 A 250 V AC 1 A 30 V DC Max. switching power 1a N.O. 1c N.C. 625 VA, 150 W 625 VA, 90 W 250 VA, 30 W 1,250 VA, 150 W 1,250 V AC, 150 W 500 V AC, 30 W Max. switching voltage 250 V AC, 110 V DC (0.3A) Max. switching current N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A Expected mechanical life (at 180 cpm)(min. operations) 107 Expected electrical life (min. operations) Type Switching capacity 5 A 125 V AC 1a 3 A 125 V AC 2 A 250 V AC 5 A 30 V DC Standard type N.O. 1c N.C. 5 A 125 V AC 2 A 250 V AC 3 A 30 V DC 2 A 125 V AC 1 A 250 V AC 1 A 30 V DC 10 A 125 V AC 1a 5 A 250 V AC 5 A 30 V DC High capacity type N.O. 1c N.C. 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 3 A 125 V AC 2 A 250 V AC 1 A 30 V DC No. of operations 5×104 2×105 2×105 105 5×104 2×105 105 2×105 2×105 105 5×104 5×104 105 5×104 5×104 105 2×105 2×105 105 Coil (at 20°C 68°F) Nominal operating power 1a: 200 mW 1c: 400 mW Characteristics Max. operating speed 20 cpm Initial insulation resistance*1 Initial Between open contacts breakdown voltage*2 Between contacts and coil Min. 1,000 MΩ at 500 V DC 1a: 1,000 Vrms for 1 min. 1c: 750 Vrms for 1 min. 4,000 Vrms for 1 min. Surge voltage between contact and coil*3 8,000 V Operate time*4 (at nominal voltage) Approx. 5 ms Release time*4 (at nominal voltage)(without diode) Approx. 2 ms Temperature rise*5 Max. 45°C Shock Functional*6 resistance Destructive*7 Min. 294 m/s2 {30 G} Min. 980 m/s2 {100 G} Functional*8 Vibration resistance Destructive 98 m/s2 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm Conditions for operation, transport and storage*9 (Not freezing and condensing at low temperature) Ambient temp.*10 Humidity –40°C to +85°C –40°F to +185°F 5 to 85% R.H. Unit weight Approx. 7 g .25 oz Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA *3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time *5 Measured conditions Standard type High capacity type Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70°C 158°F Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70°C 158°F *6 Half-wave pulse of sine wave: 11ms; detection time: 10µs *7 Half-wave pulse of sine wave: 6ms *8 Detection time: 10µs *9 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). *10 When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with 20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range. 71 JQ TYPICAL APPLICATIONS • Air conditioners • Refrigerators • Microwave ovens • Heaters ORDERING INFORMATION Ex. JQ 1a P B 12 V Contact arrangement Contact capacity Coil insulation class 1a: 1 Form A Nil: Standard 1: 1 Form C P: High capacity Nil: Class E coil insulation B: Class B coil insulation UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type Coil voltage (DC) 5, 6, 9, 12, 18, 24, 48* V TYPES AND COIL DATA at 20°C 68°F 1 Form A High capacity type Standard type Part No. JQ1a-5V JQ1a-6V JQ1a-9V JQ1a-12V JQ1a-18V JQ1a-24V JQ1aP-5V JQ1aP-6V JQ1aP-9V JQ1aP-12V JQ1aP-18V JQ1aP-24V JQ1-5V JQ1-6V JQ1-9V JQ1-12V JQ1-18V JQ1-24V JQ1-48V JQ1P-5V JQ1P-6V JQ1P-9V JQ1P-12V JQ1P-18V JQ1P-24V JQ1P-48V Nominal voltage, V DC 5 6 9 12 18 24 5 6 9 12 18 24 5 6 9 12 18 24 48 5 6 9 12 18 24 48 Pick-up voltage, V DC (min.) 3.75 4.5 6.75 9 13.5 18 4 4.8 7.2 9.6 14.4 19.2 3.75 4.5 6.75 9 13.5 18 36 4 4.8 7.2 9.6 14.4 19.2 38.4 Drop-out voltage, V DC (min.) 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 2.4 0.25 0.3 0.45 0.6 0.9 1.2 2.4 Standard type 1 Form C High capacity type Nominal operating current, mA 40 33.3 22.2 16.7 11.1 8.3 40 33.3 22.2 16.7 11.1 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 80 66..


JQ1P-9V JQ1P-12V JQ1P-18V


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)