DatasheetsPDF.com

CJX2-0901 Dataheets PDF



Part Number CJX2-0901
Manufacturers CNC
Logo CNC
Description AC CONTACTOR
Datasheet CJX2-0901 DatasheetCJX2-0901 Datasheet (PDF)

Deliver Power ToOur Life AC CONTACTOR B 06 CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660VAC 50Hz or 60Hz, rated current up to 95A, for making & breaking,frequently starting & controllingthe AC mot or. Com bin ed with the auxiliary contact block, timer delay & machineinterlocking device etc, itbecomesthe del ay co nt ac to r, mechanical interlocking contactor, star-delta starter. Withthe thermal relay, it is combined into the electromagnetic starter..

  CJX2-0901   CJX2-0901



Document
Deliver Power ToOur Life AC CONTACTOR B 06 CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660VAC 50Hz or 60Hz, rated current up to 95A, for making & breaking,frequently starting & controllingthe AC mot or. Com bin ed with the auxiliary contact block, timer delay & machineinterlocking device etc, itbecomesthe del ay co nt ac to r, mechanical interlocking contactor, star-delta starter. Withthe thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-4. Volts 50Hz 60Hz 50/60Hz 24 42 48 110 220 230 240 380 400 415 440 500 660 B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 B6 D6 E6 F6 M6 - U6 Q6 - - R6 - - B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 - - Name CJX2 Rated current Auxiliary contact Pole number Coil voltage * Frequency . Rated current (A) Auxiliary contact Normal open (NO) Normal close (NC) 19 -1 112 - 1 118 - 1 125 - 1 132 - 1 40 1 - 50 - 1 65 1 - 80 - 1 95 1 - Note:3 pole is normal type,not remarked in the type name. Type CJX2-0910*. CJX2-0901*. CJX2-1210*. CJX2-1201*. CJX2-1810*. CJX2-1801*. CJX2-2510*. CJX2-2501*. CJX2-3210*. CJX2-3201*. CJX2-4011*. CJX2-5011*. CJX2-6511*. CJX2-8011*. CJX2-9511*. CHANGCHENG ELECTRICAL EQUIPMENT GROUP CO.,LTD Deliver Power ToOur Life AC CONTACTOR Type CJX2-09 CJX2-12 CJX2-18 CJX2-25 CJX2-32 CJX2-40 CJX2-50 CJX2-65 CJX2-80 CJX2-95 Main circuit characteristic Rated operation voltage (Ue) V 380,660 Rated insulation voltage (Ui) V 690 Rated thermal current (Ith) A 20 20 32 40 50 60 80 80 125 125 B AC-3.380V A 9 12 18 25 32 40 50 65 80 95 07 Rated operation current (Ie) AC-3,660V A 6.6 8.9 12 18 21 34 39 42 49 55 AC-4.380V A 3.5 5 7.7 8.5 12 18.5 24 28 37 41 AC-4.660V A 1.5 2 3.8 4.4 7.5 9 12 14 17.3 21.3 Max. power of 3 phase motor controlled AC-3.220V kW 2.2 3 4 AC-3.380V kW 4 5.5 7.5 AC-3.660V kW 5.5 7.5 10 5.5 7.5 11 15 18.5 22 11 15 18.5 22 30 37 15 18.5 30 33 37 45 25 45 55 Electrical life AC-3 10000 t AC-4 10000 t 100 20 80 80 20 15 60 10 Machinical life 10000 t 1000 800 800 600 Operation frequency AC-3 AC-4 t/h t/h 1200 300 600 600 300 300 600 300 Matching fuse type RT16-20 RT16-20 RT16-32 RT16-40 RT16-50 RT16-63 RT16-80 RT16-80 RT16-100 RT16-125 Matching thermal relay type JR28-25 JR28-25 JR28-25 JR28-25 JR28-36 JR28-93 JR28-93 JR28-93 JR28-93 JR28-93 Wiring capacity mm2 1.5 1.5 2.5 4 6 10 16 16 25 35 Coil Control power voltage (Us) AC V 36,110,127,220,380 Allowed control circuit voltage Close Open V V 85%~110%Us 20%~75%Us (AC) Close VA 70 110 200 Coil power Keeping VA 8 11 20 Loss power W 1.8~2.7 3~4 6~10 Auxiliary contact Rated thermal current (Ith) A 10 Rated operation voltage (Ue) AC DC V V 380 220 Rated control capacity AC-15 DC-13 VA W 360 33 C2 C1 Cmax Amax 2- 4.5 35mm 76max 50 60 35 Note C CJX2 C1 CJX2+F4 Pic.1 CJX2-09,12,18 C2 CJX2+SK2-2/3 Type CJX2-09,12 CJX2-18 Amax 47 47 Cmax 82 87.


CJX2-0910 CJX2-0901 CJX2-1210


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)