Document
SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 2.0 Amperes
DB201S THRU
DB207S
FEATURES
* Good for automation insertion * Surge overload rating - 60 amperes peak * Ideal for printed circuit board * Reliable low cost construction utilizing molded * Glass passivated device * Polarity symbols molded on body * Mounting position: Any * Weight: 1.0 gram
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 oC ambient temperature unless otherwise specified. resistive or inductive load.
.310 (7.9) .290 (7.4)
.255 (6.5) .245 (6.2)
.042 (1.1) .038 (1.0)
.013 (.330)
.003 (.076) .410 (10.4) .360 (9.4)
.346 (8.8) .307 (7.8)
0.135 (3.4) 0.115 (2.9)
DB-S
.009 (0.229)
.060 (1.524) .040 (1.016)
.205 (5.2) .195 (5.0)
MAXIMUM RATINGS (At TA = 25oC unless otherwise noted) RATINGS
Maximum Recurrent Peak Reverse Voltage Maximum RMS Bridge Input Voltage Maximum DC Blocking Voltage Maximum Average Forward Output Current at TA = 40oC Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method)
Typical Current Squared Time
Typical Thermal Resistance (Note 2)
Operating and Storage Temperature Range
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS
Maximum Forward Voltage Drop per Bridge Element at 2.0A DC Maximum Reverse Current at Rated DC Blocking Voltage per element
@TA = 25oC @TA = 125oC
Note: 1.”Fully ROHS compliant”,”100% Sn plating(Pb-free). 2. Thermal Resistance: Mounted on PCB.
SYMBOL VRRM VRMS VDC IO
IFSM
I2T RθJA RθJL TJ,TSTG
SYMBOL VF
IR
Dimensions in inches and (millimeters)
DB201S DB202S DB203S DB204S DB205S DB206S DB207S UNITS 50 100 200 400 600 800 1000 Volts 35 70 140 280 420 560 700 Volts 50 100 200 400 600 800 1000 Volts 2.0 Amps
60 Amps
14.9 40 15 -55 to + 150
A2S 0C/ W 0C
DB201S DB202S DB203S DB204S DB205S DB206S DB207S UNITS
1.1 Volts
5.0 uAmps 0.5 mAmps
2009-12 REV: A
RATING AND CHARACTERISTICS CURVES ( DB201S THRU DB207S )
PEAK FORWARD SURGE CURRENT, (A)
60 8.3mS Single Half Sine-Wave JEDEC Method
50
40 30
20
10
0 0 2 4 6 10 20 40 60
NUMBER OF CYCLES AT 60Hz
FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
100
TA = 25 OC
100
10
1.0
0.1 0 20 40 60 80 100 120 140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
AVERAGE FORWARD CURRENT, (A)
INSTANTANEOUS FORWARD CURRENT, (A)
10
1
0.1 TJ = 25 OC
Pulse Width = 300mS 1% Duty Cycle 0.01 0 0.5 1.0 1.5 2.0 2.5 INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.2 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
2.0
1.0
60 Hz RESISTIVE OR INDUCTIVE LOAD 0 20 40 60 80 100 120 140 150
AMBIENT TEMPERATURE, (OC)
FIG.4 TYPICAL FORWARD CURRENT DERATING CURVE
INSTANTANEOUS REVERSE CURRENT, (uA)
Mounting Pad Layout
.410 Max. (10.4 Max.)
.205 (5.2) .195 (5.0)
.042 Min. (1.10 Min.)
.060 Min. (1.52 Min.)
Dimensions in inches and (millimeters)
Marking Description
-+
Part No.
DB20X
~V Y W W
Year – code:
(Y:Last digit of year)
~
Week – code: (WW:01~52)
Rectron Logo
Voltage-code
1-------50V 5-------600V 2-------100V 6-------800V 3-------200V 7-----1000V 4-------400V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE DB-S
PACKING CODE -C
EA PER BOX 4,000
INNER BOX SIZE (mm)
450*140*84
CARTON SIZE (mm)
464*305*283
EA PER CARTON 24,000
WEIGHT(Kg) 18.44
REEL PACK
PACKAGE
PACKING EA PER CODE REEL
COMPONENT TAPE SPACE
SPACE(mm)
(mm)
REEL DIA (mm)
CARTON SIZE EA PER GROSS
(mm)
CARTON WEIGHT(Kg)
DB-S
-T 1,000
9.5
52
176
355*360*350
8,000
9.80
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
.