,() 。 ,,, ,。 ,。 The series of KSD306、 KSD306-B and KSD308 that is of double-pole structure falls in the category of manual reset type thermal protector. The product series, safety and reliable, is used in high-duty electric water heater for overheating protection. When the instant snap of bimetal disc occurs at certain temperature, two contacts separate promptly by means of mechanical transition and simultaneously two-phase circuit disconnects in order to completely cut off power supply. Pressing reset lever will restore the power supply.
/BASIC TECHNICAL PARAMETER
KSD306 KSD306-B
KSD308
◎ (): Rated current(resistive): KSD306: 30A KSD306-B: 16A KSD308: 16A
◎ Type of Disconnection All-pole disconnection.
◎ Resistance 50mΩ(,DC10V,1A) Below 50mΩ (Numeric m & mV meter, by volt-ampere standard, DC10V, 1A)
◎ Insulation Resistance DC500VDC500V100MΩ。 With a DC 500V megger, borne DC 500V, the tested value is over 100MΩ.
◎ Dielectric Strength 2000V 50Hz, ,。 Parts between electriferous components and non-electriferous ones can bear 2000V 50Hz AC current, which is nearly sine wave, for one minute as bearing test. Resulted no breakdown, no flashover.
◎ Class of Temperature Characteristics Manual reset
◎ Max. OT KSD306: 125℃ KSD306-B: 125℃ KSD308: 100℃
◎ Min. OT KSD306: 40℃ KSD306-B: 40℃ KSD308: 40℃
◎ Tmax: 185℃
/SAFETY CERTIFICATE
KSD306
OT
Rates
OT range
Life
250V 30A
40-125℃ 1,0000
KSD306-B
KSD308
Certificate
OT
Rates
OT range
CQC: 03002007918 TUV: R50099180
250V 16A
40-125℃
Life 10,000
Certificate
OT
Rates
OT range
CQC: 12002084388 TUV: R50099180
250V 16A
≤100℃
Life 10,000
Certificate
CQC: 03002007918 TUV: R50099180
FSTB MAKES LIFE BETTER
86-757-87575702
FOSHAN TONGBAO CO.,LTD.
TONGBAO HUALONG CONTROLS CO.,LTD.
/SHAPE AND DIMENSION
KSD306KSD308
KSD306 AND KSD308 SERIES
UNITS:MM
KSD306
KSD306-B
KSD308
/NOMENCLATURE
KSD30
6 8
-□/□□□R□…
,(0) Special specification code, in number(no marks when the number is 0)
“” Refers to manual reset.
, Code for terminal: in number
: Current rating: in number
:,1/10 Code for temperature requirement: in number; 1/10 of nominal operating temperature.
Series No.
/INSTALLATION AND DIRECTION FOR USE
:。 Method of earth: By means of the metal cup of thermostat connected in the earthing metal part.
90%、、。 The thermostat should work in environment with humidity not higher than 90%,free of caustic, flammable gas and conducting dust.
,, 。 When the thermostat is used to sense the temperature of solid items, its cover should be clung to the heating part of such items. Meanwhile, heat-conducting silicon grease, or other heat media of similar nature, should be applied to the cover’s surface.
,。 The top of the cup must not be pressed to sink, so as to avoid adverse effect on the thermostat’s temperature sensitivity or its other functions.
!;, ,。 Liquids must be kept out of the thermostat’s inner part! The base must avid any force that could lead to crack; it should be kept clear and away from the pollution of electric substance to prevent insulation weakening that leads to short-circuited damages.
,。 The terminals should be bent, or else, the reliability of electric connection will be influenced.