AC Relays
www.DataSheet4U.com
SSR 120/240V 40A (RMS)
Non-Zero crossing Models
Futures
* Large capacity(40Arms) in spite of the ...
Description
www.DataSheet4U.com
SSR 120/240V 40A (RMS)
Non-Zero crossing Models
Futures
* Large capacity(40Arms) in spite of the standard package.
* LowNoiseSwitchingandRushCurrent
Function
* SinglePole,Single Throw NormallyOpen
D2N240CD
D2N140CD D2N240CD D2N140CF D2N240CF D2N140CG D2N240CG
D2N240CF
D2N240CG
Characteristics and Ratings
Parameter
Output
Rated Voltage A.C.Line Voltage Range Operating Frequency Maximum Load Current Non-repetitive One Cycle Surge Current Minimum Operating Current Maximum off-state Leakage Current Maximum on-sateVoltageDrop
Response Time
Input
Control Signal Voltage Range Input Impedance Pick-up Voltage Drop-out Voltage
Input/Output
AC Isolation Voltage (BetweenInput , Output Terminals and Base) Capacitance (Between input and output
Operating Temperature Range Storage Temperature Range
Symbol
Characteristics / Ratings
Unit
D2N140CD D2N140CF D2N140CG D2N240CD D2N240CF D2N240CG
V(RMS) V(RMS)
f IT(RMS) ITSM Iop(RMS) Ileak(RMS) VT(RMS) T(rps)
120 240
60 to 140
60 to 280
47 to 63
40
400
120
2.0 (@120Vrms)
4.0 (@240Vrms)
1.6
1/2 Cycle + 1mS
V V HZ A A mA mA V -
IIN(DC) R(IN) PUV DOV
3 to 6 260 3.0
10 to 18 860 10.0
18 to 28 3 to 6 1360 260 18.0 3.0 1.0
10 to 18 860 10.0
18 to 28 1360 18.0
V ohm V V
Viso(RMS)
C(i-o) Top Tstg
1500
100 -20 to +80 -25 to +85
V
pF °C °C
www.DataSheet4U.com
www.DataSheet4U.com
D2N240CG
...