DatasheetsPDF.com

GP20 Dataheets PDF



Part Number GP20
Manufacturers Yokogawa
Logo Yokogawa
Description Paperless Recorder
Datasheet GP20 DatasheetGP20 Datasheet (PDF)

<> <> General Specifications GS 04L52B01-01EN GP10/GP20 Paperless Recorder (Portable type) GX90XA/GX90XD/GX90YD I/O Modules  OVERVIEW The GP10/GP20 are portable type paperless recorders that display real-time measured data on a touch screen and save data on an external storage medium (SD card). ● The number of measurement data is a maximum of 48 channels in GP10, and a maximum of 100 channels in GP20. ● The GP10/GP20 have the large internal memory (GP10/GP20: 500MB), and pr.

  GP20   GP20


Document
<> <> General Specifications GS 04L52B01-01EN GP10/GP20 Paperless Recorder (Portable type) GX90XA/GX90XD/GX90YD I/O Modules  OVERVIEW The GP10/GP20 are portable type paperless recorders that display real-time measured data on a touch screen and save data on an external storage medium (SD card). ● The number of measurement data is a maximum of 48 channels in GP10, and a maximum of 100 channels in GP20. ● The GP10/GP20 have the large internal memory (GP10/GP20: 500MB), and prolonged record and preservation are possible. ● As the input signal, a DC voltage, thermocouple, resistance temperature detector, or contact signal can be set to each channel. ● Input and output have module structure and it can extend them easily. (GP10: max. 3, GP20: max. 10) ● A module type is three types, an analog input, a digital input, and a digital output. ● The intuitive operation by flick, pinch in, pinch out, and swipe are possible. ● The past trend under recording can be seamlessly displayed on a trend screen. ● Moreover, the measurement data of the time specified on the calendar screen can be searched and displayed. ● Various functions, such as a freehand message, a PDF/Excel output of a report file, a direct output to a network printer, a scale movement of a trend display, and a buzzer sound, are equipped. ● It can be hooked up to network via Ethernet, which enables to inform by Email and to monitor on Web site as well as to transfer files by using FTP. Also, it can communicate with Modbus/RTU or Modbus/ TCP. ● A setup of GP can be performed on-line from the web browser on PC. A setup by off-line is also possible. ● Universal Viewer software allows a PC to display waveforms on its screen and to print out waveforms.  MAIN UNIT SPECIFICATIONS ■ FUNCTIONAL SPECIFICATION Input Specifications Please see "INPUT/OUTPUT MODULE SPECIFICATIONS." Display Functions Display groups: Number of groups; GP10: 30, GP20: 50 Number of channels that can be assigned to each group; GP10: 10, GP20: 20 Scan interval: 100*, 200*, 500 ms*, 1, 2, 5 s * Cannot be specified if an electromagnetic relay scanner type (Type Suffix Code: -T1) analog input module is in use. GP10 GP20 Display color (Trend/Bar graph/Digital display): Channel: Select from 24 colors A desired display color can be selected freely using its RGB value. Background: Select from white or black Display type: ● Trend display (T-Y) Display method: Direction: Horizontal, vertical Trend interval: 5*, 10*, 15*, 30 s/div, 1, 2, 5, 10, 15, 20, 30 min/div, 1, 2, 4, 10 h/div * Cannot be specified if an electromagnetic relay scanner type analog input module is in use. Trend line width: Thick, normal, thin Scale; GP10: Max. 6, GP20: Max. 10 Current value bar graph, color scale band, and alarm point marks can be displayed on the scale. Moving scale; Scale can be moved on any waveform. A bitmap image scale can be attached. Others; Grid (Auto, 4 to 12), Trip line, Message, Zone display, Partial expanded display ● Historical trend display (T-Y display) Redisplays the display data or event data in the internal memory or external storage medium Time axis operation: The time axis can be reduced or expanded. Data search: Waveforms from the internal memory can be displayed through the specification of a date and time, calendar, each summary Moving scale; A bitmap image scale can be attached. All historical trends can be displayed in one screen. ● Bar graph display Direction: Vertical or horizontal Scale: Display a scale for each channel Color scale band, and alarm point marks can be displayed on the scale. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan GS 04L52B01-01EN ©Copyright Octorber 2012 7th Edition May. 7, 2013 <> <> ● Digital display Displays measured values numerically A DI input state can be displayed as an arbitrary character string (0=Off/1=On, etc.) Update rate: 0.5 s ● Overview display Display format: All channels (GP10: Max. 30, GP20: Max. 100), each groups Displays the measured values of all channels and the alarm statuses ● Alarm summary display Displays a log of up to 1000 alarms Specify an alarm with the cursor and jump to the corresponding section on the historical trend display. ● Message summary display Time and content of up to 500 messages (including 50 add messages) Specify a message with the cursor and jump to the corresponding section on the historical trend display. ● Memory summary display Displays the information (up to 500) of the data in the memory Specify a file with the cursor and jump to the corresponding section on the historical trend display. ● Report display Displays the report data residing in the internal memory For more details, see "MATHEMATICAL FUNCTIONS WITH REPORT FUNCTION (/MT)." ● Log display Displays the event log, error log, communication log, FTP log, Web log, e-mail log, SNTP log, DHCP l.


GP10 GP20 MM3Z2V4T1


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)