Part Number AZ2505
Manufacturers American Zettler
Logo American Zettler
Description POWER RELAY
Datasheet AZ2505 DatasheetAZ2505 Datasheet (PDF)

AZ2505 120 AMP LATCHING POWER RELAY FEATURES • Low cost • 120 Amp switching • Heavy loads to 30000 VA • 4 kV dielectric • Single or Dual Coil Latching available • Multiple Termination Options • UL pending CONTACTS Arrangement Ratings Rated Load UL, CUR Material Resistance SPST-NO (1 Form A) SPST-NC (1 Form B) Resistive load: Max. switched power: 30000 VA Max. switched current: 120 A Max. switched voltage: 250 VAC 60 A at 250 VAC 80 A at 250 VAC 100 A at 250 VAC 120 A at 250 VAC silver alloy < .

  AZ2505   AZ2505


Document
AZ2505 120 AMP LATCHING POWER RELAY FEATURES • Low cost • 120 Amp switching • Heavy loads to 30000 VA • 4 kV dielectric • Single or Dual Coil Latching available • Multiple Termination Options • UL pending CONTACTS Arrangement Ratings Rated Load UL, CUR Material Resistance SPST-NO (1 Form A) SPST-NC (1 Form B) Resistive load: Max. switched power: 30000 VA Max. switched current: 120 A Max. switched voltage: 250 VAC 60 A at 250 VAC 80 A at 250 VAC 100 A at 250 VAC 120 A at 250 VAC silver alloy < 2 milliohms initially (6 V, 1 A voltage drop method) COIL Power At Pickup Voltage (typical) 563 mW Single Coil 1.125 W Dual Coil NOTES 1. All values at 23°C (73.4°F). 2. Relay may pull in with less than “Must Operate” value. 3. Specifications subject to change without notice. 4. Allow suitable slack on leads when wiring, and do not subject the terminals to excessive force. GENERAL DATA Life Expectancy Mechanical Electrical Minimum operations 1 x 106 1 x 104 at 60 A, 250 VAC Res. Set Time (max) 20 ms at nominal coil voltage Reset Time (max) 20 ms at nominal coil voltage Dielectric Strength 4000 VAC coil to contact (at sea level for 1 min.) 1500 VAC between open contacts Insulation Resistance 1000 megohms min. at 500 VDC Ambient Temperature At nominal coil voltage Operating -40°C (-40°F) to 85°C (194°F) Storage -40°C (-40°F) to 90°C (194°F) Vibration 0.059" DA at 10–55 Hz Operating Humidity 20 - 85%RH (non-condensing) Shock Operating 10 g Non-Operating 100 g Enclosure P.B.T. polyester Terminals Quick connect terminal Max. Solder Temp. 270°C (518°F) Max. Solder Time 5 seconds Weight 50 grams 11/20/2014 AZ2505 RELAY ORDERING DATA COIL SPECIFICATIONS -Single Coil ORDER NUMBER Nominal Coil VDC Set Voltage Reset Voltage Max. Continuous VDC VDC VDC[1] Coil Resistance ± 10% 1 Form A 1 Form B 5 3.75 4.0 6.5 25 AZ2505P1–1A–5D AZ2505P1–1B–5D 6 4.50 4.8 7.8 36 AZ2505P1–1A–6D AZ2505P1–1B–6D 9 6.75 7.2 11.7 81 AZ2505P1–1A–9D AZ2505P1–1B–9D 12 9.00 9.6 15.6 144 AZ2505P1–1A–12D AZ2505P1–1B–12D 24 18.00 19.2 31.2 576 AZ2505P1–1A–24D AZ2505P1–1B–24D Add suffix ‘E’ after A or B for 80A contacts, ‘H’ for 100A contacts, or ‘T’ for 120A contacts. Add Termination Suffix as seen in Chart below. Note[1]: Max continuous voltage should not be applied for more than 30 seconds. COIL SPECIFICATIONS -Dual Coil ORDER NUMBER Nominal Coil VDC Set Voltage Reset Voltage Max. Continuous VDC VDC VDC[1] Coil Resistance ± 10% 1 Form A 1 Form B 5 3.75 4.0 6.5 12.5 + 12.5 AZ2505P2–1A–5D AZ2505P2–1B–5D 6 4.50 4.8 7.8 18 + 18 AZ2505P2–1A–6D AZ2505P2–1B–6D 9 6.75 7.2 11.7 40.5 + 40.5 AZ2505P2–1A–9D AZ2505P2–1B–9D 12 9.00 9.6 15.6 72 + 72 AZ2505P2–1A–12D AZ2505P2–1B–12D 24 18.00 19.2 31.2 288 + 288 AZ2505P2–1A–24D AZ2505P2–1B–24D Add suffix ‘E’ after A or B for 80A contacts, ‘H’ for 100A contacts, or ‘T’ for 120A contacts. Add Termination suffix as seen in chart below. Note[1]: Max continuous voltage should not be applied for more than 30 seconds. TERMINATION OPTIONS MS Stationary Contact: Shunt Moveable Contact: Lead Wire MH Stationary Contact: Shunt Moveable Contact: Tab MC Stationary Contact: Shunt Moveable Contact: Shunt WHS Stationary Contact: Tab Moveable Contact: Lead Wire WHH Stationary Contact: Tab Moveable Contact: Tab CH Stationary Contact: Tab Moveable Contact: Shunt MECHANICAL DATA Single Coil Termination Type MS WSS Stationary Contact: Lead Wire Moveable Contact: Lead Wire WSH Stationary Contact: Lead Wire Moveable Contact: Tab CS Stationary Contact: Lead Wire Moveable Contact: Shunt *PCB Printed Circuit Board Tin Plated Terminals * Only available in 60A, 80A, and 100A version Dual Coil 11/20/2014 AZ2505 Single Coil Termination Type MH Dual Coil Single Coil Termination Type WSS Dual Coil Load Current 60A 80A 100A 120A Tab Thickness(T) 1.0mm 1.5mm 2.0mm 2.5mm 11/20/2014 Dual Coil Termination Type PCB Wiring Diagram 56 pin 1 pin 3 pin 1 pin 3 56 pin 2 NOTE: 1. Single Coil Latching Version (1). After energizing Pin 3(+) and Pin 1(-), 50 ms pulse, Terminal 5 and 6 is conncected. (2). After energizing Pin 1(+) and Pin 3(-), 50 ms pulse, Terminal 5 and 6 is diconncected. 1. Double Coil Latching Version (1). After energizing Pin 2(+) and Pin 1(-), 50 ms pulse, Terminal 5 and 6 is conncected. (2). After energizing Pin 2(+) and Pin 3(-), 50 ms pulse, Terminal 5 and 6 is diconncected. 11/20/2014 .


AZ2150W AZ2505 AZ2511


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)