Description DC-DC Converter
Datasheet IEQ0548S24 DatasheetIEQ0548S24 Datasheet (PDF)

IEQ05 Series DC-DC Converter 5 Watt xxx Series• Regulated Single & Dual Output • Wide 4:1 Input Range • Compact SIP8 Package • 1500 VDC Isolation • Operating Temperature -40 °C to +90 °C • Remote On/Off • 3 Year Warranty Dimensions: IEQ05: 0.86 x 0.37 x 0.44” (21.8 x 9.3 x 11.2 mm) Models & Ratings Input voltage 4.5-18V 9-36V 18-75V Output voltage 3V3 5V 12 V 15 V 24 V ±12 V ±15 V 3V3 5V 12 V 15 V 24 V ±12 V ±15 V 3V3 5V 12 V 15 V 24 V ±12 V ±15 V Output current 1075 mA 1000 mA 417 mA 334.

  IEQ0548S24   IEQ0548S24


Document
IEQ05 Series DC-DC Converter 5 Watt xxx Series• Regulated Single & Dual Output • Wide 4:1 Input Range • Compact SIP8 Package • 1500 VDC Isolation • Operating Temperature -40 °C to +90 °C • Remote On/Off • 3 Year Warranty Dimensions: IEQ05: 0.86 x 0.37 x 0.44” (21.8 x 9.3 x 11.2 mm) Models & Ratings Input voltage 4.5-18V 9-36V 18-75V Output voltage 3V3 5V 12 V 15 V 24 V ±12 V ±15 V 3V3 5V 12 V 15 V 24 V ±12 V ±15 V 3V3 5V 12 V 15 V 24 V ±12 V ±15 V Output current 1075 mA 1000 mA 417 mA 334 mA 209 mA ±209 mA ±167 mA 1075 mA 1000 mA 417 mA 334 mA 209 mA ±209 mA ±167 mA 1075 mA 1000 mA 417 mA 334 mA 209 mA ±209 mA ±167 mA Input current(1,2) No load Full load 390 mA 515 mA 500 mA 60 mA 505 mA 510 mA 515 mA 510 mA 195 mA 255 mA 250 mA 30 mA 250 mA 250 mA 255 mA 255 mA 95 mA 130 mA 125 mA 20 mA 125 mA 125 mA 125 mA 125 mA Maximum capacitive load(3) 1000 µF 1000 µF 220 µF 100 µF 100 µF ±100 µF ±47 µF 1000 µF 1000 µF 220 µF 100 µF 100 µF ±100 µF ±47 µF 1000 µF 1000 µF 220 µF 100 µF 100 µF ±100 µF ±47 µF Notes 1. Input currents measured at nominal input voltage. 2. Input current is typically 2.5 mA at nominal input voltage when output is remotely turned off. 3. Maximum capacitive load is per output. Efficiency 76% 81% 83% 83% 82% 81% 82% 76% 81% 83% 84% 83% 82% 82% 76% 80% 83% 84% 82% 82% 83% Model number IEQ0512S3V3 IEQ0512S05 IEQ0512S12 IEQ0512S15 IEQ0512S24 IEQ0512D12 IEQ0512D15 IEQ0524S3V3 IEQ0524S05 IEQ0524S12 IEQ0524S15 IEQ0524S24 IEQ0524D12 IEQ0524D15 IEQ0548S3V3 IEQ0548S05 IEQ0548S12 IEQ0548S15 IEQ0548S24 IEQ0548D12 IEQ0548D15 1 www.xppower.com IEQ05 Series DC-DC Converter Input Characteristic Input Voltage Range Input Filter Input Surge Remote On/Off Minimum Typical Maximum Units 4.5 18 9.0 36 VDC 18.0 Internal Capacitor 75 36 50 VDC for 1 s 100 ON: open circuit OFF: 2-4 mA via 1kΩ resistor into pin 3 with respect to pin 1 Notes & Conditions 12 V nominal 24 V nominal 48 V nominal 12 V nominal 24 V models 48 V models Output Characteristic Output Voltage Initial Set Accuracy Output Voltage Balance Minimum Load Line Regulation Load Regulation Cross Regulation Transient Response Ripple & Noise Overload Protection Short Circuit Protection Maximum Capacitive Load Temperature Coefficient Minimum 3.3 Typical ±1 ±0.3 ±0.5 3 170 Maximum 30 ±2 ±2 ±0.5 ±1.0 ±5.0 5 100 0.02 Units VDC % % A % % % % deviation mV pk-pk % %/ ˚C Notes & Conditions See Models and Ratings table For dual output with balanced laods No minimum load required On dual output models when one load is varied between 25% and 100% and other is fixed at 100% Recovery within 1% in less than 500 µs for a 25% load change. 20 MHz bandwidth. Measured using 0.47 µF ceramic capacitor. Continuous, with auto recovery See Models and Ratings table General Characteristic Efficiency Isolation: Input to Output Isolation Resistance Isolation Capacitance Switching Frequency Power Density Mean Time Between Failure Weight Minimum 1500/1800 109 100 Typical 82 250 2.4 0.01 (4.8) Maximum 35.7 Units % VDC Ω pF kHz W/in3 MHrs lb (g) Notes & Conditions See Models and Ratings table 60 s/1 s At 500 VDC MIL-HDBK-217F, +25 °C GB Environmental Characteristic Operating Temperature Storage Temperature Case Temperature Humidity Cooling Case Flammability Minimum -40 -55 Typical UL 94V-0 Rated Maximum +90 +125 +90 95 Units °C °C °C %RH Notes & Conditions See Derating Curve. Non-condensing Natural convection Non conductive black plastic www.xppower.com 2 IEQ05 Series DC-DC Converter Safety Approvals Safety Agency CB UL EMC: Emissions Phenomenon Conducted Safety Standard IEC60950-1 UL/cUL60950-1 Standard EN55022 Test Level Class A Notes & Conditions ITE ITE Notes & Conditions EMC: Immunity Phenomenon ESD Radiated EFT/Burst Surge Conducted Standard EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Test Level ±8 kV air discharge, ±6 kV contact 10 V/m ±2 kV ±1 kV 10 V rms Criteria A A A A A Notes & Conditions With external capacitor, suggested part is CHEMI-CON KY 330µF/100V With external capacitor, suggested part is CHEMI-CON KY 330µF/100V 0.02 (0.5) 0.44 (11.2) 0.01 (0.25) 0 0.11 (2.7) 0.37 (9.3) Mechanical Details 0.86 (21.8) 0.82 (20.8) 0.02 (3.5) 0.08 2x0.10 0.20 3x0.10 (2.0) (2x2.54) (5.08) (3x2.54) Notes 1. 2. WAlel idgihmt:en0s.0io1nlsbsar(e40.i8n inches (mm) g) approx. Application Notes Derating Curve Bottom View 12 3 5678 0.13 (3.2) 0.02 (0.50) 3. Tolerance: X.XX±0.01 (X.X±0.25) X.XXX±0.005 (X.XX±0.13) 4. Pin Tolerance: ±0.002 (±0.05) 100 Pin Connections Pin Single 1 -Vin 2 +Vin 3 Remote On/Off 5 No Connection 6 +Vout 7 -Vout 8 No Connection Dual -Vin +Vin Remote On/Off No Connection +Vout Common -Vout Output Power (%) 0 -40 65 90 Ambient Temperature (°C) 3 www.xppower.com 22 Dec 15 .


IEQ0548S15 IEQ0548S24 IEQ0548D12


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)