DatasheetsPDF.com

A53TP50D Dataheets PDF



Part Number A53TP50D
Manufacturers Crydom
Logo Crydom
Description Three-phase solid-state relay
Datasheet A53TP50D DatasheetA53TP50D Datasheet (PDF)

Series 53TP 25-50Amp • 240/480 Vac - 3 PHASE • SCR Output • LED Status Indicator • Protective Cover Available (Part No. KS300) • Panel Mount • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) Three-phase solid state relays switch up to 530 Vrms directly to loads such as motors, transformers, heating elements, etc. Available with either AC or DC input (coil) control in zero-voltage or random turn-on switching versions. Manufactured in Crydom’s ISO 9001 Certified facility f.

  A53TP50D   A53TP50D



Document
Series 53TP 25-50Amp • 240/480 Vac - 3 PHASE • SCR Output • LED Status Indicator • Protective Cover Available (Part No. KS300) • Panel Mount • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) Three-phase solid state relays switch up to 530 Vrms directly to loads such as motors, transformers, heating elements, etc. Available with either AC or DC input (coil) control in zero-voltage or random turn-on switching versions. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. OUTPUT SPECIFICATIONS 1 M O D E L N U M B E R S Operating Voltage (47-63 Hz) [Vrms] Load Current Range 3 [Arms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (RθJC) [°C/W] Maximum I 2 t for Fusing, (8.3 msec.) [A 2 sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] 2 Max. Turn-On Time 4 Max. Turn-Off Time Power Factor (Min.) with Max. Load D53TP25D 48-530 .05-25 1200 250 1.6 1.02 260 10 500 1/2 Cycle 1/2 Cycle 0.5 D53TP50D 48-530 .05-50 1200 625 1.6 .63 1620 10 500 1/2 Cycle 1/2 Cycle 0.5 A53TP25D 48-530 .05-25 1200 250 1.6 1.02 260 10 500 10.0 msec 40.0 msec 0.5 A53TP50D 48-530 .05-50 1200 625 1.6 .63 1620 10 500 10.0 msec 40.0 msec 0.5 INPUT SPECIFICATIONS 1 Control Voltage Range Max. Turn-On Voltage Min. Turn-Off Voltage Nominal Input Impedance Typical Input Current GENERAL NOTES 1 All parameters at 25ºC and per section unless otherwise specified. 2 Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 3 Heat sinking required, for derating curves see page 2. 4 Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). DC CONTROL AC CONTROL 3-32 Vdc 90-280 Vrms (60Hz) 3.0 Vdc 90 Vrms 1.0 Vdc 10 Vrms 450 Ohms 54.8k Ohms 10mA @ 5 Vdc 2.2mA @ 120 Vrms, 4.4mA @ 240 Vrms © 2007 CRYDOM Inc., Specifications subject to change without notice. SERIES 53TP. Rev. 100107 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre, Holyrood Close, Poole, Dorset BH17 7FJ, Email: [email protected]. GERMANY: +49 (0)180 3000 506 AVAILABLE OPTIONS -10 Non-Zero Cross, Instantaneous Turn-On Example: D53TP50D-10 DP 2 Controlled, 1 Linked (A1-A2) Example: D53DP50D P Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200 Vpk. Not Suitable For Capacitive Loads. Example: D53TP50DP H Heat Trasfer Pad (Attached) Example: D53TP50DH Series 53TP 25-50Amp • 240/480 Vac - 3 PHASE GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base Insulation Resistance (Min.) @ 500 Vdc 4000 Vrms 10 9 Ohm Max. Capacitance Input/Output 8 pF Ambient Operating Temperature Range -40 to 80ºC Ambient Storage Temperature Range -40 to 125ºC MECHANICAL SPECIFICATIONS Weight: (typical) 10.3 oz. (315g) Encapsulation: Thermally Conductive Epoxy Terminals: Screws and Saddle Clamps Furnished 10-32 TERMINAL (6 PLACES ) 2.125 1.875 (47.6) (54.0) 4.09 (103.8) 0.21 (5.3) 1.18 (30.0) A1 B1 A2 B2 C1 INPUT STATUS LED C2 + - INPUT 2.89 (73.4) 0.79 (20.1) Crydom Heat Sinks offer excellent thermal management and are per fectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. .39 REF (10.0) 1.56 (39.6) 3.62 (91.9) .78 (19.8) 1.36 (34.5) 6-32 TERMINAL (2 PLACES ) All dimensions are in inches (millimeters) .79 (20.1) .94 (24.0) .125 (3.2) BASE PLATE THICKNESS Screw Torque Requirements: 6-32 Screws - 10 in. lbs. (1.1Nm), 8-32 and 10-32 Screws - 20in. lbs. (2.2Nm) (Screws dry without grease.) Base Plate Temp [ºC] Power Dissipation CURRENT DERATING CURVES 60 A53DP25D, D53DP25D .5ºC/W 1ºC/W 80 1.5ºC/W 100 60 40 105 A53TP25D, D53TP25D 0.5ºC/W 1ºC/W 100 105 Base Plate Temp [ºC] Power Dissipation 110 40 1.5ºC/W 110 20 115 20 115 120 120 0 5 10 15 20 25 20 40 60 80 Load Current [Arms] Max Ambient Temp. [ºC] A53DP50D, D53DP50D 120 0.25ºC/W 90 90 95 0.5ºC/W 100 1ºC/W 60 105 1.5ºC/W 110 30 115 120 Base Plate Temp [ºC] Power Dissipation 0 5 10 15 20 25 20 40 60 80 Load Current [Arms] Max Ambient Temp. [ºC] A53TP50D, D53TP50D 180 90 .25ºC/W 150 95 .5ºC/W 120 100 90 105 1ºC/W 110 60 1.5ºC/W 115 30 120 0 10 20 30 40 50 20 40 60 80 Load Current [Arms] Max Ambient Temp. [ºC] 0 10 20 30 40 50 20 40 60 80 Load Current [Arms] Max Ambient Temp. [ºC] Base Plate Temp [ºC] Power Dissipation APPROVALS UL E116950 CSA LR81689 VDE 5941 UG SERIES 53TP Rev. 100107 PAGE 2 OF 3 © 2007 CRYDOM Inc., Specifications subject to change without notice. For.


A53TP25D A53TP50D D53TP25D


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)