DatasheetsPDF.com

GBU1007 Dataheets PDF



Part Number GBU1007
Manufacturers GW
Logo GW
Description SINGLE PHASE 10 AMP BRIDGE RECTIFIERS
Datasheet GBU1007 DatasheetGBU1007 Datasheet (PDF)

GBU1001 THRU GBU1007 SINGLE PHASE 10 AMP BRIDGE RECTIFIERS VOLTAGE RANGE 50 to 1000 Volts CURRENT 10 Amperes FEATURES * Ideal for printed circuit board * Low forward voltage * Low leakage current * Polarity: marked on body * Mounting position: Any .880(22.3) .860(21.8) GBU .232(5.9) .213(5.4) .100(2.54) .085(2.16) .047(1.2) .035(0.9) .161(4.1) .134(3.4) AC + .073(1.85) .057(1.45) .720(18.29) .680(17.27) .210(5.33) .190(4.83) SPACING .024(0.6) .016(0.4) Dimensions in inches and (mil.

  GBU1007   GBU1007



Document
GBU1001 THRU GBU1007 SINGLE PHASE 10 AMP BRIDGE RECTIFIERS VOLTAGE RANGE 50 to 1000 Volts CURRENT 10 Amperes FEATURES * Ideal for printed circuit board * Low forward voltage * Low leakage current * Polarity: marked on body * Mounting position: Any .880(22.3) .860(21.8) GBU .232(5.9) .213(5.4) .100(2.54) .085(2.16) .047(1.2) .035(0.9) .161(4.1) .134(3.4) AC + .073(1.85) .057(1.45) .720(18.29) .680(17.27) .210(5.33) .190(4.83) SPACING .024(0.6) .016(0.4) Dimensions in inches and (millimeters) .139(3.5) .133(3.4) .752(19.1) .720(18.3) .106(2.7) .091(2.3) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating 25 C ambient temperature uniess otherwies specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. TYPE NUMBER Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current GBU1001 GBU1002 GBU1003 GBU1004 GBU1005 GBU1006 GBU1007 UNITS 50 100 200 400 600 800 1000 V 35 70 140 280 420 560 700 V 50 100 200 400 600 800 1000 V at Tc=100 C Peak Forward Surge Current, 8.3 ms single half sine-wave 10 A superimposed on rated load (JEDEC method) Maximum Forward Voltage Drop per Bridge Element at 5.0A D.C. Maximum DC Reverse Current Ta=25 C 220 1.1 5.0 A V A at Rated DC Blocking Voltage Operating Temperature Range, TJ Storage Temperature Range, TSTG Ta=100 C 500 -65 +150 -65 +150 A C C 308 AVERAGE FORWARD CURRENT,(A) RATING AND CHARACTERISTIC CURVES (GBU1001 THRU GBU1007) 18 16 14 12 10 8 6 4 2 0 0 FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE Single Phase Half Wave 60Hz Resistive Or Inductive Load 20 40 60 80 100 120 140 CASE TEMPERATURE,( C) 160 PEAK FORWARD SURGE CURRENT,(A) FIG.2-MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT 250 200 150 100 50 Tj=25 C 8.3ms Single Half Sine Wave JEDEC method 0 1 5 10 50 100 NUMBER OF CYCLES AT 60Hz FIG.3-TYPICAL FORWARD CHARACTERISTICS 50 10 3.0 1.0 0.1 Tj=25 C Pulse Width 300us 1% Duty Cycle .01 0 .2 .4 .6 .8 1.0 1.2 1.4 FORWARD VOLTAGE,(V) REVERSE LEAKAGE CURRENT, ( A) FIG.4-TYPICAL REVERSE CHARACTERISTICS 50 10 3.0 Tj=100 C 1.0 0.1 Tj=25 C .01 0 20 40 60 80 100 120 140 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) INSTANTANEOUS FORWARD CURRENT,(A) 309 .


GBU1006 GBU1007 GBU601


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)