Data Sheet
FEATURES
RS-485 transceiver with electrical data isolation Complies with ANSI TIA/EIA-485-A and ISO 8482: 1987(E) 500 kbps data rate Slew rate-limited driver outputs Low power operation: 2.
5 mA maximum Suitable for 5 V or 3.
3 V operations (VDD1) High common-mode transient immunity: 25 kV/μs True fail-safe receiver inputs Chatter-free power-up/power-down protection 256 nodes on bus Thermal shutdown protection Safety and
regulatory approvals
UL recognition: 2500 V rms for 1 minute per UL 1577
VDE certificates of conformity DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12 VIORM = 560 V peak
Operating temperature range: −40°C to +85°C
APPLICATIONS
Low power RS-485/RS-422 networks Isolate...