Part Number
|
HTFS400-P-SP7 |
Manufacturer
|
LEM |
Description
|
Current Transducer |
Published
|
Dec 28, 2021 |
Detailed Description
|
Current Transducer HTFS 400-P/SP7
For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separatio...
|
Datasheet
|
HTFS400-P-SP7
|
Overview
Current Transducer HTFS 400-P/SP7
For the electronic measurement of currents: DC, AC, pulsed.
.
.
, with galvanic separation between the primary circuit and the secondary circuit.
IP N = 400 A
Electrical data
All data are given with RL = 10 kΩ
IP N
Primary nominal RMS current
IP M
Primary current, measuring range
Uout
Output voltage (Analog) @ IP
IP = 0
Uref
Reference voltage
Uref Output voltage 1)
Uref Output impedance
Uref Load impedance
RL
Load resistance
Rout
Output internal resistance
CL
Load capacitance
UC
Supply voltage (±5 %)
IC
Current consumption @ UC = 3.
3 V
400
A
±600
A
Uref ±(0.
77 × IP/IP N) V
Uref ±0.
025
V
1.
65 ±0.
025
V
...
Similar Datasheet