Part Number
|
HNC-100P |
Manufacturer
|
LEM |
Description
|
Current Transducer HNC- 050~100P |
Published
|
Mar 26, 2005 |
Detailed Description
|
Current Transducer HNC- 050 .. 100P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic i...
|
Datasheet
|
HNC-100P
|
Overview
Current Transducer HNC- 050 .
.
100P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 50 .
.
100 A
Electrical data
Primary nominal DC current Primary current measuring range Type
IPN (A)
50 100
IP (A)
0 .
.
± 75 0 .
.
± 140 HNC - 050P HNC - 100P HNC - 050P HNC - 100P
RM ISN KN VC IC Vd
Measuing resistance Second nominal current Turns ratio
60 .
.
90 50 1 : 1000
60 .
.
80 50 1 : 2000
Ω mA V mA kV
Features
• Hall effect measuring principle • Galvanic isolation between primary • Isolation voltage 2500 V • Low power consumption
and secondary circuit
Supp...