DatasheetsPDF.com

FA-PV

Part Number FA-PV
Manufacturer LEM
Description Current Transducer FA-050 ~100PV
Published Mar 30, 2005
Detailed Description Current Transducer FA-050 .. 100PV For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic is...
Datasheet FA-PV




Overview
Current Transducer FA-050 .
.
100PV For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 50 .
.
100 A Electrical data Primary nominal DC current Primary current measuring range Type IPN (A) 50 100 IP (A) 0 .
.
± 70 0 .
.
± 130 FA - 050PV FA - 050PV FA - 100PV FA - 100PV VOUT IC VC Vd Output voltage @ ± IPN , RL = 10 kΩ , T A = 25°C ± 4 Current consumpution 16 + IPN /1000 Features V mA V kV ±4 16+ IPN /2000 ± 15 2.
5 Supply voltage (± 5 %) R.
m.
s.
voltage for AC isolation test, AC50/60Hz, 1 min • Hall effect measuring principle • PC Board Mount Type • Low ...