Detailed Description
|
Current Transducer FA-050 .. 100PV
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic is...
|
Datasheet
|
FA-PV
|
Overview
Current Transducer FA-050 .
.
100PV
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 50 .
.
100 A
Electrical data
Primary nominal DC current Primary current measuring range Type
IPN (A)
50 100
IP (A)
0 .
.
± 70 0 .
.
± 130 FA - 050PV FA - 050PV FA - 100PV FA - 100PV
VOUT IC VC Vd
Output voltage @ ± IPN , RL = 10 kΩ , T A = 25°C ± 4 Current consumpution 16 + IPN /1000
Features
V mA V kV
±4 16+ IPN /2000 ± 15 2.
5
Supply voltage (± 5 %) R.
m.
s.
voltage for AC isolation test, AC50/60Hz, 1 min
• Hall effect measuring principle • PC Board Mount Type • Low ...