Part Number
|
HY20-P |
Manufacturer
|
LEM |
Description
|
Current Transducers HY 5 to 25-P |
Published
|
Apr 2, 2005 |
Detailed Description
|
Current Transducers HY 5 to 25-P
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic iso...
|
Datasheet
|
HY20-P
|
Overview
Current Transducers HY 5 to 25-P
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
5 .
.
25 A
Electrical data
Primary nominal r.
m.
s.
current IPN (A) 5 10 12.
5 15 20 25 Primary current measuring range IP (A) ± 15 ± 30 ± 37.
5 ± 45 ± 60 ± 75 Primary conductor (mm) Type
Features
HY 5-P HY 10-P HY 12-P HY 15-P HY 20-P HY 25-P
∅ 0.
7 ∅ 1.
1 ∅ 1.
4 ∅ 1.
4 2 x ∅ 1.
2 1) 2 x ∅ 1.
4 1)
• Hall effect measuring principle • Galvanic isolation between primary • Isolation voltage 2500 V~ • Compact design for PCB mounting • Low power consumption • Extended measuring rang...