Part Number AV100-2000
Manufacturer LEM
Description Voltage Transducer
Published May 31, 2007
Detailed Description Voltage Transducer AV 100-2000 For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation...
Datasheet AV100-2000




Overview
Voltage Transducer AV 100-2000 For the electronic measurement of voltages : DC, AC, pulsed.
.
.
, with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit).
VPN = 2000 V Electrical data VPN VPmax Primary nominal r.
m.
s.
voltage Primary voltage measuring range Non-measurable overload Primary input resistance Measuring resistance @ VC=11.
4V @ VC=22.
8V Secondary nominal r.
m.
s.
current Supply voltage (± 5 %) Current consumption R.
m.
s.
voltage for AC isolation test, 50 Hz, 1 min Max Common mode voltage and R.
m.
s.
voltage for partial discharge extinction @ 10pC 2000 V ± 30001) V 4500 (1s/h) VDC 17.
8M Ω RM min RM max 0 47 Ω 0 184 Ω 50 mA DC± 1...