Absolute Maximum Ratings
Parameter...
|
Datasheet
|
BP5062A
|
Overview
Data Sheet
100VAC Input/−12VDC (500mA) Output
Non-Isolated AC/DC Converter
BP5062A
Absolute Maximum Ratings
Parameter Input voltage Output current ESD endurance Operating temperature range Storage temperature range
Symbol Vi Io
Vsurge Topr Tstg
Limits −190 500
2 −20 to +80 −25 to +105
Unit V mA kV C C
Electrical Characteristics
Parameter
Symbol Min.
Typ.
Max.
Unit
Conditions
Input voltage range
Vi −113 −141 −180 V DC (80 to 127VAC)
Output voltage
Vo −11.
0 −12.
0 −13.
0 V Vi= −141V, Io=300mA
Output current
Io 0 − 500 mA Vi= −141V
∗1
Line regulation
Vr − 0.
05 0.
15 V Vi= −113V to −170V, Io=300mA
Load regulation
Vl − 0.
07 0.
20 V Vi= −141V, Io=0 to 300mA
Output ripple voltage ...