CMA1 Relay
1.
COIL DATA 1-1.
Nominal
Voltage 1-2.
Coil Restistance 1-3.
Operate
Voltage 1-4.
Release
Voltage 1-5.
Coil Power
6,12,24VDC Refer to Coil Data Chart Refer to Coil Data Chart Refer to Coil Data Chart 360mW 800mW
2.
CONTACT DATA 2-1.
Contact Form 2-2.
Contact Material 2-3.
Contact Rating
2-4.
Max.
Switching
Voltage 2-5.
Max.
Switching Current 2-6.
Max.
Switching Power 2-7.
Contact Resistance 2-8.
Life
Electrical Mechanical
A-1 form A C-1 form C Ag Alloy 15A 14VDC Resistive ( C-1 form C) 20A 14VDC Resistive ( A-1 form A) 75VDC 20A 280W
100m 6VDC 1A
100,000 operations at nominal load 10,000,000 operations
3.
GENERAL DATA 3-1.
Insulation Resistance 3-2.
Dielectric Strength
3-3.
Operate Time 3-4.