Pulse Sensors Series Hall Sensor
Characteristics
Rated operating distance 1.
3 .
.
.
2.
5 mm for modules 1 … 4
Dynamic version, 5 Hz to 20 kHz
DC three-pole, push-pull output (plus- and minus-switching)
Rotation speed detection with high operating frequency (up to 20 kHz) and high geometrical resolution (module ≥ 1)
Hall element switches are unsuitable for detecting slots, for axial approach, and for non-magnetic materials
Dimensions
HAD-11ms60b1-5Sd7 Ref.
no.
13.
32-05
Technical data (Unless otherwise specified UB = 24 V, TU ≈ 23 °C, and IL = 0)
Rated operating distances sn (10 kHz)
Effective operating distance sr Operating
voltage UB
Permissible ripple
voltage Current consumption without l...