LAL2009-51
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and 250V working
voltage RoHS Compliant Excellent THD performance Operating Temperature -40°C to 85°C
OCL: Leakage Inductance:
D.
C.
R:
Hi-POT : Turn Ratio:
Electrical Specifications @25℃
PIN 1-5= 410uH ±10% @ 10KHz/0.
1V/Ser.
PIN 1-5= 10uH Max.
@ 100KHz/0.
1V
PIN 1-4 = 790 mohm Max.
PIN 2-5 = 790 mohm Max.
PIN 9-6 = 450 mohm Max.
PIN 10-7 = 350 mohm Max.
PRI.
– SEC.
=1875VAC/60Hz/2Seconds/1mA PIN1-4 : PIN 10-6 = 1.
6±2% :1
Dimensions (Units: mm)
Schematic
LAL**** LinkCom
X Data Code G
13.
50±0.
5
C
12.
85±0.
5 A
PIN1
B
10 6
D
51 PIN3 CUT OFF 2.
50
10.
00±0.
5
10.
00
3.
5±...