General Purpose Low Power PCB Relays
Power PCB Relay RT2 bistable
n 2 pole 8A, 2 form C (CO) contacts n Polarized bistable version with 1 or 2 coils n 5kV/10mm coil-contact n Reinforced insulation
SCHRACK
Typical applications Battery powered equipment or applications with “memory function”.
Zb
Approvals
VDE Cert.
No.
40007571, UL E214025, cCSAus 1142018
Technical data of approved types on request.
Contact Data
Contact arrangement
2 form C (CO)
Rated
voltage
250VAC
Max.
switching
voltage
400VAC
Rated current
8A, UL: 10A
Limiting continuous current
8A, UL: 10A
Limiting making current, max.
4s, duty factor 10% 15A
Breaking capacity max.
2000VA
Contact mat...