Installation Instructions for the SS49/SS19 Series Analog Position Sensors
ISSUE 2
PK 88740
PERSONAL INJURY • DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
SS49/SS19 ELECTRICAL CHARACTERISTICS
Supply
Voltage Supply Current Output Type Output
Voltage @ 0 Gauss, 25°C Sensitivity (measured between -400 and +400 gauss), mV/G Operating Temperature 4 to 10 VDC 4 mA typ.
Analog Sourcing 1.
75 to 2.
25 V @ 5 V Min.
0.
60 Typ.
0.
90 Max.
1.
25
-40 to +100 °C (-40 to 212 °F)
SOLDERING/ASSEMBLY SS49 Support leads du...