DatasheetsPDF.com

FR603

Diodesorporated
Part Number FR603
Manufacturer Diodesorporated
Description 6.0A FAST RECOVERY RECTIFIER
Published Apr 23, 2005
Detailed Description FR601 - FR607 6.0A FAST RECOVERY RECTIFIER Features · · · · · Low Reverse Recovery Time Low Reverse Current Low Forward ...
Datasheet PDF File FR603 PDF File

FR603
FR603


Overview
FR601 - FR607 6.
0A FAST RECOVERY RECTIFIER Features · · · · · Low Reverse Recovery Time Low Reverse Current Low Forward Voltage Drop High Current Capability Plastic Material: UL Flammability Classification Rating 94V-0 A B A C Mechanical Data · · · · · Case: R-6, Molded Plastic Terminals: Axial Leads, Solderable per MIL-STD-202 Method 208 Polarity: Color Band Denotes Cathode Weight: 1.
7 grams (approx.
) Mounting Position: Any R-6 Dim A B C D Min 25.
4 8.
6 1.
2 8.
6 D Max ¾ 9.
1 1.
3 9.
1 All Dimensions in mm Maximum Ratings and Electrical Characteristics Characteristic Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking voltage Maximum Average Forward Rectified Current 9.
5mm Lead Length @ TA=75°C Peak Forward Surge Current 8.
3ms single half sine-wave superimposed on rated load (JEDEC method) Maximum Instantaneous Forward Voltage @ 6.
0A DC Maximum DC Reverse Current at Rated Blocking Voltage @ TA = 25°C Maximum Full Load Reverse Current Full Cycle Average 9.
5mm lead length @ TL = 55°C Maximum Reverse Recovery Time (Note 1) Typical Junction Capacitance (Note 2) Operating and Storage Temperature Range Symbol VRRM VRMS VDC I(AV) IFSM VF IR IR Trr CJ TJ, TSTG FR 601 50 35 50 @ TA = 25°C unless otherwise specified.
FR 602 100 70 100 FR 603 200 140 200 FR 604 400 280 400 6.
0 300 1.
3 10 150 150 200 -65 to +175 250 500 FR 605 600 420 600 FR 606 800 560 800 FR 607 1000 700 1000 Unit V V V A A V mA mA ns pF °C Notes: 1.
Reverse Recovery Test Conditions: IF =0.
5A, IR =1.
0A, IRR =0.
25A 2.
Measured at 1.
0MHz and applied reverse voltage of 4.
0V.
DS26004 Rev.
C1-3 1 of 2 FR601-FR607 IFsm, PEAK FORWARD SURGE CURRENT (AMPERES) 8 I(AV), AVERAGE FORWARD CURRENT 600 8.
3ms Single Half Sine-Wave JEDEC Method 6 500 400 300 200 100 0 1 10 100 NUMBER OF CYCLES AT 60 Hz Fig.
2, Max Non-Repetitive Peak Surge Current 4 2 0 0 25 50 75 100 125 150 175 TA, AMBIENT TEMPERATURE (°C) Fig.
1, Typical Forward Current Derating Curve IF, INSTANTANEOUS FORWARD C...