DatasheetsPDF.com

LPT60

ETC
Part Number LPT60
Manufacturer ETC
Description (LPT6x) Universal input / Remote sense on main output / Low output ripple / Overvoltage protection
Published Sep 26, 2005
Detailed Description 60 Watts LPT60 Series Total Power: Input Voltage: # of Outputs: 60-80 Watts 85-264 VAC 120-300 VDC Triple Electrical ...
Datasheet PDF File LPT60 PDF File

LPT60
LPT60


Overview
60 Watts LPT60 Series Total Power: Input Voltage: # of Outputs: 60-80 Watts 85-264 VAC 120-300 VDC Triple Electrical Specs Input Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 1.
5 A max.
(RMS) @ 115 VAC 70% typical at full load (60% for LPT61) FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.
5 mA @ 50/60 Hz, 264 VAC input Input current Efficiency EMI filter Special Features • • • • • • • • • • Universal input 3” x 5” footprint Remote sense on main output Built-in EMI filter Low output ripple Adjustable main output Overvoltage protection Overload protection 110 KHz switching frequency LPX60 enclosure kit available Safety ground leakage current Output Maximum power 60 W for convection (LPT61, 35 W); 80 W with 30 CFM forced air (LPT61, 55 W) -5, +10% minimum ±2% on output 1; ±5% on outputs 2,3 20 ms @ 60 W load, 115 VAC nominal line Short circuit protection on all outputs.
Case overload protected @ 110-145% above peak rating 5.
7-6.
7 VDC on main output LPT61: 3.
6 to 4.
6 VDC Compensates for 0.
5 V lead drop min.
Will operate without remote sense connected.
Reverse connection protected.
Adjustment range Cross regulation Hold-up time Overload protection Environmental Overvoltage protection Operating temperature: 0° to 50°C ambient derate each output at 2.
5% per degree from 50° to 70°C Electromagnetic susceptibility: designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min.
dwell at four major resonances 0.
75G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.
04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions VDE UL CSA NEMKO BABT CB CE Remote sense Safety 0805/EN60950 (IEC950) UL1950 CSA 22.
2-234 Level 3 EN 60950/EMKO-TUE (74-sec) 203 EN60950/...