Astec America
Part Number LPS40
Manufacturer Astec America
Description 40 Watts
Published Nov 15, 2008
Detailed Description Embedded Power for Business-Critical Continuity LPS40 Series 40 Watts www.DataSheet4U.com Rev. 04.13.06 LPS40 Series 1...
Datasheet PDF File LPS40 PDF File

LPS40
LPS40


Overview
Embedded Power for Business-Critical Continuity LPS40 Series 40 Watts www.
DataSheet4U.
com Rev.
04.
13.
06 LPS40 Series 1 of 3 RoHS Total Power: Input Voltage: # of Outputs: 40-55 Watts 85-264 VAC 120-300 VDC Single Electrical Specifications Special Features • • • • • • • • • • • • Universal input 3" x 5" footprint Less than 1U high Remote sense Terminal block option (-T) Built-in EMI filter Low output ripple Adjustable output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available Input Input range Frequency Inrush current Input current Efficiency EMI filter Safety ground leakage current 85-264 VAC; 120-300 VDC 47-440 Hz <18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C 1A max.
(RMS) @ 115VAC 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 class B conducted <0.
5 mA @ 50/60 Hz, 264 VAC input Output Maximum power Adjustment range Hold-up time Overload protection 40W for convection; 55W with 30CFM forced air -5, +10% minimum Safety UL1950 E132002 CSA 22.
2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P94100375 (74-sec) 203 CB Certificate and report 1119, 1125, 1126, 1127 CE Mark (LVD) UL CSA 20ms @ 40W load, 115VAC nominal line Short circuit protection on all outputs Case overload protected @ 110 -145% above peak rating Overvoltage protection 5V output; 5.
7 to 6.
7VDC.
Other outputs 10% to 25% above nominal output Remote sense Compensates for 0.
5 V lead drop minimum Will operate without remote sense connected Reverse connection protected Embedded Power for Business-Critical Continuity Rev.
04.
13.
06 LPS40 Series 2 of 3 Environmental Specifications www.
DataSheet4U.
com Operating temperature: 0° to 50°C ambient.
Derate each output 2.
5% per degree from 50° to 70°C, -20°C start up.
Storage temperature: -40°C to +85°C Temperature coefficient: ±0.
4% per °C Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidit...