DatasheetsPDF.com

LPS45

Emerson
Part Number LPS45
Manufacturer Emerson
Description AC-DC / 10W - 85W
Published Oct 25, 2009
Detailed Description Embedded Power for Business-Critical Continuity LPS40 Series 40 Watts Total Power: Input Voltage: # of Outputs: ...
Datasheet PDF File LPS45 PDF File

LPS45
LPS45


Overview
Embedded Power for Business-Critical Continuity LPS40 Series 40 Watts Total Power: Input Voltage: # of Outputs: 40 - 55 Watts 85 - 264 VAC 120 - 300 VDC Single Rev.
7.
8.
09_4 LPS40 Series  of 3 Special Features • • • • • • • • • • • • Universal input 3” x 5” footprint Less than 1U high Remote sense Terminal block option (-T) Built-in EMI filter Low output ripple Adjustable output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available Electrical Specifications Input Input ra­nge: Frequency: Inrush current: Input current: Efficiency: EMI filter: Safety ground leakage current: 85 - 264 VAC; 120 - 300 VDC 47 - 440 Hz < 18 A peak @ 115 VAC; < 36 A peak @ 230 VAC, cold start @ 25 °C 1 A max.
(RMS) @ 115 VAC 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 class B conducted < 0.
5 mA @ 50/60 Hz, 264 VAC input Output Maximum power: Adjustment range: Hold-up time: Overload protection: 40 W for convection; 55 W with 30CFM forced air -5, +10% minimum 20 ms @ 40 W load, 115 VAC nominal line Short circuit protection on all outputs Case overload protected @ 110 -145% above peak rating Safety • UL UL60950 E132002 • CSA CSA 22.
2-234 Level 3 LR53982C • NEMKO EN 60950/EMKO-TUE P94100375 (74-sec)203 • CB Certificate and report 1119, 1125, 1126, 1127 • CE Mark (LVD) Overvoltage protection: 5 V output; 5.
7 to 6.
7 VDC.
Other outputs 10% to 25% above nominal output Remote sense: Compensates for 0.
5 V lead drop minimum Will operate without remote sense connected Reverse connection protected Embedded Power for Business-Critical Continuity Environmental Specifications Operating temperature: 0° to 50 °C ambient.
Derate each output 2.
5% per degree from 50° to 70 °C, -20 °C start up.
Storage temperature: -40 °C to +85 °C Temperature coefficient: ± 0.
4% per °C Electromagnetic Designed to meet IEC 801, -2, ...