Harmonic Filters. FN3440 Datasheet

FN3440 Filters. Datasheet pdf. Equivalent

FN3440 Datasheet
Recommendation FN3440 Datasheet
Part FN3440
Description Passive Harmonic Filters
Feature FN3440; DATASHEET ECOsine Passive FN 3440 ECOsine® 50 Hz, IP 00, Passive Harmonic Filters The industry stan.
Manufacture Schaffner
Datasheet
Download FN3440 Datasheet




Schaffner FN3440
DATASHEET ECOsine Passive FN 3440
ECOsine® 50 Hz, IP 00, Passive Harmonic Filters
The industry standard for 6-pulse rectifiers and
motor drives
The most compact 5% THID filter available
Open Frame Filters (IP 00)
Excellent behavior under partial load
conditions
Filters for diode and thyristor rectifiers without
DC-link choke
Technical specifications
Nominal operating voltage
Nominal motor drive input current rating
Operating frequency
Total harmonic current distortion THID*
Total demand distortion TDD
Efficiency
High potential test voltage
Protection category
Cooling
Overload capability
Ambient temperature range
Design corresponding to
Flammability corresponding to
MTBF @ 45°C/415 V (Mil-HB-217F)
Earthing System
3 x 380 VAC to 415 VAC ±10%
1.1 to 200 kW
50 Hz ±1 Hz
<5% at rated power
According to IEEE 519
>98.5% for rated voltage and power
P –> E 2160 VAC (1 s)
IP 00
External cooling**
1.6x rated current for 1 minute, once per hour
–25°C to +45°C fully operational
–25°C to +88°C transport and storage
+45°C to +70°C derated operation***
Filter: UL 61800-5-1, EN 61800-5-1
Chokes: EN 61558-2-20 or EN 60076-6
UL 94 V-2
>200,000 hours
TN, TT, IT
****System requirements: THVD <2%, line voltage unbalance <1%
****Note: performance specifications in this brochure refer to six-pulse diode rectifiers.
****SCR rectifier front-ends will produce different results, dependent upon the firing angle of the thyristors.
****Please check the air cooling requirements' table on page 3 of this document.
****I_derated = I_nom*sqrt((70°C-Tamb)/25°C)
Approvals
Features and benefits
Schaffner ECOsine harmonic filters represent an
economical solution to the challenge of load-applied
harmonics mitigation in three-phase power systems.
With a plug-and-play approach and more compact
dimensions than comparable products, they can be
quickly installed and easily commissioned. They
increase the reliability and service life of electric
installations, help utilize electric sytem capacity
better, and are the key to meet Power Quality
standards such as IEEE 519. ECOsine filters reshape
your distorted current back to the desired sinusoidal
waveform. Schaffner ECOsine filters can be applied to
virtually any kind of power electronics with front-end
six-pulse rectifiers, 3-phase diode or thyristor bridges,
where harmonic current distortion needs to be
reduced to defined limits.
Typical applications
Equipment with front-end six-pulse rectifier
Motor drives
Factory automation equipment
Water/wastewater treatment facilities
Fan and pump applications
HVAC installations
Mission-critical processes
DC fast chargers
Typical electrical schematic



Schaffner FN3440
2 PQ/Harmonics
Filter selection table
Filter
FN3440-1-110-E0X
FN3440-2-110-E0X
FN3440-4-112-E0X
FN3440-6-112-E0X
FN3440-8-112-E0X
FN3440-11-113-E0X
FN3440-15-113-E0X
FN3440-19-113-E0X
FN3440-22-115-E0X
FN3440-30-115-E0X
FN3440-37-115-E0X
FN3440-45-115-E0X
FN3440-55-115-E0X
FN3440-75-116-E0X
FN3440-90-116-E0X
FN3440-110-118-E0X
FN3440-132-118-E0X
FN3440-160-118-E0X
FN3440-200-118-E0X
Filter terminals
Terminal designation
110
112
113
115
116
118
Schaffner Group Datasheets 2016
Rated load power
@ 400 V/50 Hz
[kW]
1.1
2.2
4
5.5
7.5
11
15
19
22
30
37
45
55
75
90
110
132
160
200
Weight
[kg]
9.3
11
22.9
38.5
74.5
139.5
259.0
Terminals
110
110
112
112
112
113
113
113
115
115
115
115
115
116
116
118
118
118
118
Frame size
A
A
B
C
C
D
D
D
E
E
E
E
E
G
G
H
H
H
H
Screw thread
M3
M4
M6
M8
M8
M10
Screw Torque Value
[Nm]
0.5
1.2
3.0
8
8
10
Pressure plate
(width or diameter)
[mm]
7
10
16
20
17.5
21
Frame size
A
B, C
D
E
G
H



Schaffner FN3440
3 PQ/Harmonics
Mechanical data
Frame sizes A-E
Schaffner Group Datasheets 2016
Frame sizes G and H
Dimensions FN 3440
Frame
A
B
C
D
E
G
H
Air cooling requirements
Frame size
A, B, C
D
E
G
H
R
340
405
460
540
680
920
1115
Drill pattern
ST
120 7
120 7
150 7
180 11
220 11
280 11
390 11
Min air volume
[m3/h]
0
128
204
408
612
Base
U
360
370
425
483
705
960
1150
X
302
370
430
491
634
863
1053
Volume
YZ
160 185
180 206
210 221
260 252
290 339
353 396
462 456







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)