460 Watts. DS460S-3-005 Datasheet

DS460S-3-005 Watts. Datasheet pdf. Equivalent

Part DS460S-3-005
Description 460 Watts
Feature POWER Data Sheet Total Output Power: 460 Watts +12 Vdc Stand-by Output Wide Range Input Voltage: 90.
Manufacture Artesyn
Datasheet
Download DS460S-3-005 Datasheet

POWER Data Sheet Total Output Power: 460 Watts +12 Vdc Stan DS460S-3-005 Datasheet
Recommendation Recommendation Datasheet DS460S-3-005 Datasheet





DS460S-3-005
POWER
Data Sheet
Total Output Power: 460 Watts
+12 Vdc Stand-by Output
Wide Range Input Voltage:
90 - 264 Vac
Special Features
ƒƒ Active power factor correction
ƒƒ EN61000-3-2 harmonic compliance
ƒƒ Active AC inrush control
ƒƒ 1U X 2U form factor
ƒƒ +12 Vdc output
ƒƒ +12 Vdc stand-by
ƒƒ Hot plug operation
ƒƒ N + 1 redundant
ƒƒ Active current sharing
ƒƒ Built-in cooling fan
ƒƒ I2C communication interface bus
ƒƒ PMBus compliant
ƒƒ EEPROM for FRU data
ƒƒ Two years warranty
Safety
ƒƒ UL/cUL 60950 (UL Recognized)
ƒƒ NEMKO 60950
ƒƒ Cb Certificate and report
ƒƒ CE Mark (LVD)
DS460S
460 Watts
Electrical Specifications
Input
Input ra­nge:
90 - 264 Vac
Frequency:
47 - 63 Hz, single phase AC
Inrush current:
30 Apk maximum inrush current
Efficiency:
92% typical at high line 50% load
Conducted EMI:
FCC Subpart J EN55022 Class A
Radiated EMI:
FCC Subpart J EN55022 Class A
Power factor:
0.99 typical
Leakage current:
1.0 mA @ 240 Vac
Hold up time:
10 ms minimum
Output
Main DC voltage:
+12.3 V @ 36.0 A
Stand-By:
+12 V @ 2.3 A
Adjustment range:
Factory Set
Regulation:
11.85 - 12.45 Vdc
11.40 - 12.6 Vdc
Overcurrent:
+12 Vdc; latches off if overcurrent lasts over 1 second,
Trip point 120% - 150% of rated current.
Overvoltage:
+12 Vdc; 13.6 - 15.0 Vdc
+12 Vsb; 13.6 - 15.0 Vdc
Turn-on delay:
1 - 1.5 seconds
Main output rise time:
10 - 30 mS, monotonic rise



DS460S-3-005
DS460S Data Sheet
Logic Control
PS_PRESENT (S4):
PSOK (S6):
I-Mon (S7):
PS INTERRUPT (S4):
PS ON (S8):
Used to sense the number of power supplies in the system (operational or not) and provide hot plug insertion and
removal functionality by controlling main outputs during hot plug insertion and removal by employing following
circuitry. When the unit is removed from the system the fast shut down signal quickly turns OFF main outputs and
discharges output capacitors. This signal is the shortest gold finger pin on the signal connector to allow for last
make, first break configuration.
Combined indicator of AC input and main 12 V DC output. This is a three level signal to indicate different stages
as follows.
AC not OK and DC not OK – Signal status shall be LOW (< 0.6 V)
AC OK and DC not OK – Signal status shall be LOW (< 0.6 V)
AC OK and DC OK – Signal status shall be HIGH (> 3.0 V)
AC not OK and DC OK – Signal status shall be Middle Level (Between 2 V and 2.5 V)
DC OK threshold is defined as when the 12 V output is greater than 11.5 V.
DC not OK threshold is defined as when the 12 V output is less than 11.4 V & greater than 11.3 V.
Provides both the load sharing function (as a feedback for output regulation droop function) and 12 V output
current information.
The signal behavior in response to certain operating condition changes in the power supply as defined in the
Firmware Specification section. This signal shall be pulled up to maximum 5 V logic level external to the PS.
Required to remotely turn on/off the power supply. PSON# is an active low signal that turns on the main 12 V DC
output. When this signal is not pulled low by the system, or left open, the 12 V output is turned off. This signal is
pulled to a standby voltage by a pull-up resistor internal to the power supply. Refer to On/Off Timing for timing dia-
gram in TRN. When in off or standby condition, the main 12 V DC output will be less than 50 mV with respect to
output return.
Environmental Specifications
Operating temperature:
Storage temperature:
Altitude, operating:
Electromagnetic susceptibility/Input transients:
RoHS & lead-free compliant
Humidity:
Shock and vibration specificatons:
MTBF (Demonstrated):
-10 °C to 50 °C
-40 °C to +85 °C
10,000 ft.
-EN61000-3-2
-EN61000-4-2, 4.3, 4-4, -4-5, 4-6, 4-11
No tantalum caps.
5 to 90% RH, non-condensing
Complies with Astec Std. Specifications
500K Hrs at full load, 50 °C
Ordering Information
Model Number
Nominal Output
Voltage Set Point
Set Point Total Minimum
Tolerance Regulation Current
Maximum
Current
Output Ripple
P/P
Over Current
Stand-by Air Flow
DS460S-3-002
12.3 Vdc
± 0.2%
+5%
1 A 36.0 A
120 mV 45.9 A - 57.5 A* 12.0 V @ 2.3 A STD
DS460S-3-003
12.3 Vdc
± 0.2%
+5%
1 A 36.0 A 120 mV 45.9 A - 57.5 A* 12.0 V @ 2.3 A REV
DS460S-3-004
(5,000 m)
12.3 Vdc
± 0.2% ± 5.0% 1.0 A
36.0 A
120 mV 45.9 A - 57.5 A* 12.0 V @ 2.3 A STD
DS460S-3-005
(5,000 m)
12.3 Vdc
± 0.2% ± 5.0% 1.0 A
36.0 A
120 mV 45.9 A - 57.5 A* 12.0 V @ 2.3 A REV
*Overcurrent latches off if overcurrent lasts over 1 second, otherwise it is auto recovery.





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)