DatasheetsPDF.com

RF Contactors. RT22-4070-A31NB Datasheet

DatasheetsPDF.com

RF Contactors. RT22-4070-A31NB Datasheet






RT22-4070-A31NB Contactors. Datasheet pdf. Equivalent




RT22-4070-A31NB Contactors. Datasheet pdf. Equivalent





Part

RT22-4070-A31NB

Description

High Voltage Vacuum RF Contactors



Feature


HighVoltageVacuumRFContactors RT22-4070 -A31NB and RT22-4070-A317B .312 DIA. TH RU 4 MTG. HOLES RT22-4070-A31NB and RT 22-4070-A317B are vacuum contactors wit h DPDT contact arrangements. These unit s can also be used as SPDT contactors b y wiring the contacts in parallel. Thes e contactors are commonly used in anten na switching for high power RF circuits , such as those en.
Manufacture

JENNINGS

Datasheet
Download RT22-4070-A31NB Datasheet


JENNINGS RT22-4070-A31NB

RT22-4070-A31NB; countered in transmitters. Voltage R atings Rated Voltage (kV Peak) @ 2 MHz Operating Voltage (VACR RMS) @ 50/60 H z RT22-4070-A317B RT22-4070-A31NB 2 2 115 22 230 Current Rating Continu ous (Amps RMS) @ 2 MHz Max. Contact Re sistance (MΩ) @ Rated Continuous Curre nt Max. Capacitance Across Open Contac ts (pF) Max. Capacitance Contacts to F rame (pF) 40 500.


JENNINGS RT22-4070-A31NB

2.5 1.0 40 500 2.5 1.0 Specificati ons Max. Opening Time (msec.) Max. Clo sing Time (msec.) Actuator Type Actua tor Voltage (VACR) Max. Pull-In Curren t (Amps) Dielectric Withstand to Frame (V) @ 60 Hz RMS for 1.0 min. Max. Wei ght (lbs.) Mechanical L .


JENNINGS RT22-4070-A31NB

.

Part

RT22-4070-A31NB

Description

High Voltage Vacuum RF Contactors



Feature


HighVoltageVacuumRFContactors RT22-4070 -A31NB and RT22-4070-A317B .312 DIA. TH RU 4 MTG. HOLES RT22-4070-A31NB and RT 22-4070-A317B are vacuum contactors wit h DPDT contact arrangements. These unit s can also be used as SPDT contactors b y wiring the contacts in parallel. Thes e contactors are commonly used in anten na switching for high power RF circuits , such as those en.
Manufacture

JENNINGS

Datasheet
Download RT22-4070-A31NB Datasheet




 RT22-4070-A31NB
HighVoltageVacuumRFContactors
RT22-4070-A31NB
and
RT22-4070-A317B
.312 DIA. THRU
4 MTG. HOLES
RT22-4070-A31NB and RT22-4070-A317B are vacuum contactors with DPDT
contact arrangements. These units can also be used as SPDT contactors by
wiring the contacts in parallel. These contactors are commonly used in antenna
switching for high power RF circuits, such as those encountered in transmitters.
Voltage Ratings
Rated Voltage (kV Peak) @ 2 MHz
Operating Voltage (VACR RMS) @ 50/60 Hz
RT22-4070-A317B RT22-4070-A31NB
22
115
22
230
Current Rating
Continuous (Amps RMS) @ 2 MHz
Max. Contact Resistance (MΩ) @ Rated Continuous Current
Max. Capacitance Across Open Contacts (pF)
Max. Capacitance Contacts to Frame (pF)
40
500
2.5
1.0
40
500
2.5
1.0
Specifications
Max. Opening Time (msec.)
Max. Closing Time (msec.)
Actuator Type
Actuator Voltage (VACR)
Max. Pull-In Current (Amps)
Dielectric Withstand to Frame (V) @ 60 Hz RMS for 1.0 min.
Max. Weight (lbs.)
Mechanical Life (operations)
Auxiliary Contact Rating @ 115/230 VAC RMS (Amps)
300
300
Latching
115
0.4
1250
12
250,000
15
300
300
Latching
230
0.3
1250
12
250,000
15
HIGH VOLTAGE TERMINALS
.187 DIA. THRU 4 MTG HOLES
4 VACUUM INTERRUPTERS
HIGH VOLTAGE TERMINALS
1/4-20 TERMINALS
STUDS 4 PLC’S
CONTROL TERMINALS
8.2
7.00
3.2
1.6
LOCATION OF
FL JENNINGS
IDENTIFICATION
.6
7.06
10.5 ± .187
1.7
LOCATION OF WIRING DIAGRAM
5.2
6.2
www.jenningstech.com | 408-292-4025
HighVoltageVacuumRFContactors 43











Recommended third-party RT22-4070-A31NB Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)