circuit breakers. MF1-B-34-610-1-DB2-2-C Datasheet

MF1-B-34-610-1-DB2-2-C breakers. Datasheet pdf. Equivalent

Part MF1-B-34-610-1-DB2-2-C
Description Miniature hydraulic/magnetic circuit breakers
Feature M-Series General Specifications Agency Certifications The low cost M-Series utilizes the hydraulic.
Manufacture Carling Technologies
Datasheet
Download MF1-B-34-610-1-DB2-2-C Datasheet

M-Series General Specifications Agency Certifications The MF1-B-34-610-1-DB2-2-C Datasheet
Recommendation Recommendation Datasheet MF1-B-34-610-1-DB2-2-C Datasheet




MF1-B-34-610-1-DB2-2-C
M-Series General Specifications
Agency Certifications
The low cost M-Series utilizes the hydraulic magnetic principle
which provides accurate and reliable circuit protection even when
exposed to extremely hot and/or cold application environments.
Available in a choice of rocker actuator styles and colors, push
button, push-pull, paddle, and baton style handle actuators, the
Visi-Rocker® two-color actuators as well as non-illuminated or illu-
minated rocker versions with LED or neon bulbs. The exclusive
Rockerguard® bezel helps prevent inadvertent actuation. "Wiping"
contact design insures long term reliability. Various styling options
allow design flexibility.
Typical applications include power supplies, medical equipment,
and telecommunications equipment. In addition, these breakers
meet CSA Standard 22.2 No. 100 for the Generator & Welder
markets.
UL Recognized
UL Standard 1077
UL Listed
UL Standard 489A
Component Recognition Program as
Protectors, Supplementary (Guide
CCN/QVNU2, File E75596)
CSA Accepted
Communications Equipment (Guide
CCN/DITT, File E189195)
VDE Certified
TUV Certified
Component Supplementary
Protector under Class 3215 30,
File 047848 0 000
CSA Standard C22.2 No. 235
EN60934, VDE 0642 under File
10537
EN60934, under License No.
R9671109
Electrical
Table A: Lists UL Recognized and CSA Accepted configurations & performance capabilities as a Component Supplementary Protector.
NOTES FOR TABLE A
1 Polarity Sensitive
2 Available only with Special Catalog Number. Consult Factory.
3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 60 Amps maximum
18
www.carlingtech.com



MF1-B-34-610-1-DB2-2-C
M-Series General Specifications
Electrical
Table B: Lists UL Recognized,CSA Accepted and TUV and VDE Certified configurations and performance capabilities as a
Component Supplementary Protector.
NOTES FOR TABLE B
1 Polarity Sensitive
2 Available only with Special Catalog Number. Consult Factory.
3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4 TUV only, not VDE
5 Requires backup protection with a thermal magnetic circuit breaker rated 32 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C32A) for ratings greater than 15 amps,
and a thermal magnetic circuit breaker rated 16 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C16A) for ratings 15 amps and less.
Table C: Lists UL489A Listed and TUV Certified configurations and performance capabilities for use in Communications
Equipment.
NOTES FOR TABLE C
1. Available only with Special Caralog Number
www.carlingtech.com
19





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)