Part

RACM18-05SER

Description

AC/DC Converter



Feature


Features Regulated Converter • Medic al certified 2MOPP module, BF ready • Class II installations (without FG) IP68 waterproof encapsulation • Operation altitude certified up to 5000 m • No external components necessary • Energy Efficiency Level VI AC/DC Converter RACM18-ER Description The R ACM18-ER series comprises highly reliab le power conversion modules in.
Manufacture

RECOM

Datasheet
Download RACM18-05SER Datasheet


RECOM RACM18-05SER

RACM18-05SER; a potted IP68 waterproof encapsulation to withstand harsh operating conditions . With a certified operation up to 5000 m altitude and a temperature range from -20°C up to +80°C these modules are built to power medical healthcare, hous ehold, sanitary, smart building and aut omation process appliances. For easy in tegration the product line is certified to medical, househo.


RECOM RACM18-05SER

ld, as well as to ITE safety standards a nd designed to pass class B limits by m ore than 6dB margin without the need fo r any external components. 18 Watt Rou nd Shape Single Output Selection Guide Part Number RACM18-05SER (3) RACM 18-12SER (3 .


RECOM RACM18-05SER

.

Part

RACM18-05SER

Description

AC/DC Converter



Feature


Features Regulated Converter • Medic al certified 2MOPP module, BF ready • Class II installations (without FG) IP68 waterproof encapsulation • Operation altitude certified up to 5000 m • No external components necessary • Energy Efficiency Level VI AC/DC Converter RACM18-ER Description The R ACM18-ER series comprises highly reliab le power conversion modules in.
Manufacture

RECOM

Datasheet
Download RACM18-05SER Datasheet




 RACM18-05SER
Features
Regulated
Converter
• Medical certified 2MOPP module, BF ready
• Class II installations (without FG)
• IP68 waterproof encapsulation
• Operation altitude certified up to 5000m
• No external components necessary
• Energy Efficiency Level VI
AC/DC Converter
RACM18-ER
Description
The RACM18-ER series comprises highly reliable power conversion modules in a potted IP68
waterproof encapsulation to withstand harsh operating conditions. With a certified operation up to
5000m altitude and a temperature range from -20°C up to +80°C these modules are built to power
medical healthcare, household, sanitary, smart building and automation process appliances. For easy
integration the product line is certified to medical, household, as well as to ITE safety standards and
designed to pass class B limits by more than 6dB margin without the need for any external components.
18 Watt
Round
Shape Single
Output
Selection Guide
Part
Number
RACM18-05SER (3)
RACM18-12SER (3)
RACM18-24SER (3)
Input Output Output Efficiency
Voltage Range Voltage (1) Current typ. (2)
[VAC] [VDC] [A] [%]
90-264 5 2.5 81
90-264 12 1.5 82
90-264 24 0.75 83.5
Notes:
Note1: Other output voltages on request
Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25°C ambient
R
C US
REBA VEBA
Model Numbering
RACM18-__ SER (3)
Output Power
Output Voltage
Single
Notes:
Note3: Other connection types on reqeuest
2MOPP
280VAC
IEC/EN60950-1 certified
UL60950-1 certified
ANSI/AAMI ES60601-1 certified
IEC/EN60601-1 certified
IEC/EN60335-1 certified
IEC/EN61558-1 certified
IEC/EN61558-2-16 certified
IEC/EN60601-1-2 certified
EN55024/32 certified
EN55014-1 (-2) certified
CISPR32 certified
www.recom-power.com
REV.: 2/2018
MED-1




 RACM18-05SER
RACM18-ER
AC/DC Converter
Specifications (measured @ ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Internal Input Filter
Input Voltage Range
Input Current
Inrush Current
No load Power Consumption
Input Frequency Range
Minimum Load
Power Factor
Start-up Time
Rise Time
Hold-up Time
Internal Operating Frequency
Output Ripple and Noise
Condition
115VAC
230VAC
115VAC
230VAC
115VAC
230VAC
115VAC/230VAC
115VAC
230VAC
100% load at nominal Vin
20MHz BW
Efficiency vs. Load
RACM18-12SER
100
100
90 90
80 80
70 70
60 60
50 50
40 40
30
20 85VAC
115VAC
10 230VAC
0 264VAC
0 25 50 75 100
Output Load [%]
30
20
10
0
0
Min.
90VAC
47Hz
0%
Typ.
230VAC
24A
46A
40mW
0.46
180ms
200ms
15ms
15ms
65ms
100kHz
RACM18-24SER
Max.
Pi type
264VAC
500mA
150mA
75mW
63Hz
140mVp-p
85VAC
115VAC
230VAC
264VAC
25 50 75
Output Load [%]
100
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation
Transient Response
www.recom-power.com
Condition
low line to high line
0% to 100% load
100% load step change
continued on next page
REV.: 2/2018
Value
±3.0% max.
±1.0% max.
±1.0% max.
±3.0% max.
MED-2




 RACM18-05SER
RACM18-ER
AC/DC Converter
Specifications (measured @ ta= 25°C, nom. Vin (115/230VAC), full load after warm-up unless otherwise stated)
Series
Accuracy vs. Load
(@ min Vin to max. Vin)
+3.0
+2.0
+1.0
0
-1.0
-2.0
-3.0
0
RACM18-12SER
25 50 75
Output Load [%]
100
+3.0
+2.0
+1.0
0
-1.0
-2.0
-3.0
0
RACM18-24SER
25 50 75
Output Load [%]
100
PROTECTIONS
Parameter
Input Fuse
Short Circuit Protection (SCP)
Over Voltage Protection (OVP)
Over Voltage Category (OVC)
Over Current Protection (OCP)
Over Temperature Protection (OTP)
Class of Equipment
Isolation Voltage (3)
Insulation Grade
Leakage Current
Means of Protection
Medical Device Classification
Type
internal (line & neutral)
5Vout, 12Vout
24Vout
90VAC
< 1 minute
160VAC
264VAC
95°C ambient
I/P to O/P
tested for 1 minute
280VAC working voltage
Value
T2A, slow blow
continuous, auto recovery
16VDC, Latch OFF
24VDC, Latch OFF
OVCII
145% of nominal Output Current, auto recovery
180% of nominal Output Current, auto recovery
165% of nominal Output current, auto recovery
Hiccup Mode
thermal shutdown, auto recovery
Class II
4.6kVAC
reinforced
100µA max.
2MOPP
Type BF
Notes:
Note3: For repeat Hi-Pot testing, reduce the time and/or the test voltage
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Operating Altitude
Operating Humidity
Pollution Degree
MTBF
Design Lifetime
www.recom-power.com
Condition
natural convection 0.1m/s
without derating
with derating
non-condensing
according to MIL-HDBK- +25°C
217F, G.B.
+50°C
continued on next page
REV.: 2/2018
Value
-20°C to +50°C
-20°C to +80°C
+85°C
5000m
95% RH max.
PD2
563 x 103 hours
112 x 103 hours
130 x 103 hours
MED-3