DatasheetsPDF.com

Recovery Diode. 80PFR40 Datasheet

DatasheetsPDF.com

Recovery Diode. 80PFR40 Datasheet
















80PFR40 Diode. Datasheet pdf. Equivalent













Part

80PFR40

Description

Standard Recovery Diode



Feature


80PF(R)...(W) Series Vishay High Power P roducts Standard Recovery Diodes, Gene ration 2 DO-5 (Stud Version), 80 A 80P F(R)... 80PF(R)...W DO-203AB (DO-5) DO-203AB (DO-5) FEATURES • High surg e current capability • Designed for a wide range of applications • Stud ca thode and stud anode version • Wire v ersion available • Low thermal resist ance • UL approval pending •.
Manufacture

Vishay

Datasheet
Download 80PFR40 Datasheet


Vishay 80PFR40

80PFR40; Compliant to RoHS directive 2002/95/EC • Designed and qualified for multiple level PRODUCT SUMMARY IF(AV) 80 A TYPICAL APPLICATIONS • Battery charge rs • Converters • Power supplies Machine tool controls • Welding MA JOR RATINGS AND CHARACTERISTICS PARAME TER TEST CONDITIONS IF(AV) IF(RMS) IF SM I2t VRRM TJ TC 50 Hz 60 Hz 50 Hz 60 Hz Range VALUES 80 140 126 1.


Vishay 80PFR40

500 1570 11 250 10 230 400 to 1200 - 55 to 180 ELECTRICAL SPECIFICATIONS VOLT AGE RATINGS TYPE NUMBER VOLTAGE CODE 40 80PF(R)...(W) 80 120 VRRM, MAXI MUM REPETITIVE PEAK REVERSE VOLTAGE V 4 00 800 1200 VRSM, MAXIMUM NON-REPETITI VE PEAK REVERSE VOLTAGE V 500 960 1440 UNITS A °C A A A2s V °C IRRM MAXIMUM AT TJ = 150 °C mA 9 Document Number: 93526 Revision: 20-M.


Vishay 80PFR40

ay-09 For technical questions, contact: ind-modules@vishay.com www.vishay.com 1 80PF(R)...(W) Series Vishay High P ower Products Standard Recovery Diodes , Generation 2 DO-5 (Stud Version), 80 A FORWARD CONDUCTION PARAMETER SYMB OL TEST CONDITIONS Maximum average fo rward current at case temperature IF(A V) 180° conduction, half sine wave M aximum RMS forward .





Part

80PFR40

Description

Standard Recovery Diode



Feature


80PF(R)...(W) Series Vishay High Power P roducts Standard Recovery Diodes, Gene ration 2 DO-5 (Stud Version), 80 A 80P F(R)... 80PF(R)...W DO-203AB (DO-5) DO-203AB (DO-5) FEATURES • High surg e current capability • Designed for a wide range of applications • Stud ca thode and stud anode version • Wire v ersion available • Low thermal resist ance • UL approval pending •.
Manufacture

Vishay

Datasheet
Download 80PFR40 Datasheet




 80PFR40
80PF(R)...(W) Series
Vishay High Power Products
Standard Recovery Diodes,
Generation 2 DO-5 (Stud Version), 80 A
80PF(R)...
80PF(R)...W
DO-203AB (DO-5)
DO-203AB (DO-5)
FEATURES
• High surge current capability
• Designed for a wide range of applications
• Stud cathode and stud anode version
• Wire version available
• Low thermal resistance
• UL approval pending
• Compliant to RoHS directive 2002/95/EC
• Designed and qualified for multiple level
PRODUCT SUMMARY
IF(AV)
80 A
TYPICAL APPLICATIONS
• Battery chargers
• Converters
• Power supplies
• Machine tool controls
• Welding
MAJOR RATINGS AND CHARACTERISTICS
PARAMETER
TEST CONDITIONS
IF(AV)
IF(RMS)
IFSM
I2t
VRRM
TJ
TC
50 Hz
60 Hz
50 Hz
60 Hz
Range
VALUES
80
140
126
1500
1570
11 250
10 230
400 to 1200
- 55 to 180
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
TYPE NUMBER
VOLTAGE
CODE
40
80PF(R)...(W)
80
120
VRRM, MAXIMUM REPETITIVE
PEAK REVERSE VOLTAGE
V
400
800
1200
VRSM, MAXIMUM NON-REPETITIVE
PEAK REVERSE VOLTAGE
V
500
960
1440
UNITS
A
°C
A
A
A2s
V
°C
IRRM MAXIMUM
AT TJ = 150 °C
mA
9
Document Number: 93526
Revision: 20-May-09
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
1




 80PFR40
80PF(R)...(W) Series
Vishay High Power Products
Standard Recovery Diodes,
Generation 2 DO-5 (Stud Version), 80 A
FORWARD CONDUCTION
PARAMETER
SYMBOL
TEST CONDITIONS
Maximum average forward current
at case temperature
IF(AV)
180° conduction, half sine wave
Maximum RMS forward current
IF(RMS)
Maximum peak, one-cycle forward,
non-repetitive surge current
IFSM
Maximum I2t for fusing
I2t
Maximum I2t for fusing
Low level value of threshold voltage
Low level value of forward
slope resistance
Maximum forward voltage drop
I2t
VF(TO)
rf
VFM
t = 10 ms
t = 8.3 ms
No voltage
reapplied
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
100 % VRRM
reapplied
No voltage
reapplied
Sinusoidal half wave,
initial TJ = 150 °C
t = 10 ms
t = 8.3 ms
100 % VRRM
reapplied
t = 0.1 ms to 10 ms, no voltage reapplied
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ = TJ maximum
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ = TJ maximum
Ipk = 220 A, TJ = 25 °C, tp = 400 µs rectangular wave
VALUES
80
140
126
1500
1570
1260
1320
11 250
10 230
7950
7200
112 500
0.73
3.0
1.40
UNITS
A
°C
A
A
A2s
A2s
V
mΩ
V
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
Maximum junction operating and
storage temperature range
TJ, TStg
Maximum thermal resistance,
junction to case
RthJC
DC operation
Maximum thermal resistance,
case to heatsink
RthCS Mounting surface, smooth, flat and greased
Not lubricated thread, tighting on nut (1)
Maximum allowable
mounting torque (+ 0 %, - 10 %)
Lubricated thread, tighting on nut (1)
Not lubricated thread, tighting on hexagon (2)
Lubricated thread, tighting on hexagon (2)
Approximate weight
Case style
See dimensions - link at the end of datasheet
Notes
(1) Recommended for pass-through holes
(2) Torque must be appliable only to hexagon and not to plastic structure, recommended for holed heatsink
VALUES
- 55 to 180
UNITS
°C
0.30
K/W
0.25
3.4
(30)
2.3
(20)
N·m
4.2
(lbf · in)
(37)
3.2
(28)
15.8
g
0.56
oz.
DO-203AB (DO-5)
www.vishay.com
2
For technical questions, contact: ind-modules@vishay.com
Document Number: 93526
Revision: 20-May-09




 80PFR40
80PF(R)...(W) Series
Standard Recovery Diodes,
Vishay High Power Products
Generation 2 DO-5 (Stud Version), 80 A
ΔRthJC CONDUCTION
CONDUCTION ANGLE SINUSOIDAL CONDUCTION
RECTANGULAR CONDUCTION
TEST CONDITIONS
UNITS
180°
0.14
0.10
120°
0.16
0.17
90°
0.21
60°
0.30
0.22
0.31
TJ = TJ maximum
K/W
30°
0.50
0.50
Note
• The table above shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC
180
80PF(R) Series
170
RthJC = 0.3 K/W
160
Conduction Angle
150
140
180°
130
120°
90°
120
30° 60°
110
0 10 20 30 40 50 60 70 80 90
Average Forward Current (A)
Fig. 1 - Current Ratings Characteristics
180
80PF(R) Series
RthJC (DC) = 0.3 K/W
170
160
Conduction Period
150
140
130
120
0
30°
60°
90°
120°
180°
DC
20 40 60 80 100 120 140
Average Forward Current (A)
Fig. 2 - Current Ratings Characteristics
140
120
100
80
60
40
20
0
0
180°
120°
90°
60°
30°
RMS Limit
1 K/W
1.5 K/W
2 K/W
3 K/W
Conduction Angle 5 K/W
80PF(R) Series
Tj = 180°C
10 20 30 40 50 60 70 800 30 60 90 120 150 180
Average Forward Current (A) Maximum Allowable Ambient Temperature (°C)
Fig. 3 - Forward Power Loss Characteristics
Document Number: 93526
Revision: 20-May-09
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
3




Recommended third-party 80PFR40 Datasheet