transducer DF-C10. DF0.1-C10 Datasheet

DF0.1-C10 DF-C10. Datasheet pdf. Equivalent

DF0.1-C10 Datasheet
Recommendation DF0.1-C10 Datasheet
Part DF0.1-C10
Description DC Current transducer DF-C10
Feature DF0.1-C10; DC Current transducer DF-C10 For the electronic mesurement of low DC currents, with galvanic isolati.
Manufacture LEM
Datasheet
Download DF0.1-C10 Datasheet




LEM DF0.1-C10
DC Current transducer DF-C10
For the electronic mesurement of low DC currents, with galvanic
isolation between the primary (High power) and the secondary circuits
(Electronic circuit)
Preliminary
IPN = 10..500mA
Electrical data
Primary nominal
current
IPN (mA.t)
10
20
50
100
300
500
Primary current
range
IP (mA.t)
16
38
80
160
480
800
IOC Overload capacity
VOUT Analog Output signal @ ±IPN
Vc Supply voltage
IC Current consumption (max)
RL Load resistance
Vd Isolation test voltage1)
Analogue Output
signal
VOUT (V)
0-10
0-10
0-10
0-10
0-10
0-10
Type
DF 0.01 C10
DF 0.02 C10
DF 0.05 C10
DF 0.1 C10
DF 0.3 C10
DF 0.5 C10
30
± 10
± 12...15
20
2
5000
A.t
V
VDC
mA
k
VAC
Features
DC Measurement
Low current transducer
Panel mounting
Bipolar voltage supply
Extended measuring range
Advantages
Accuracy-Dynamic performance data
X Accuracy2) of reading @±12V, TA=25°C
εL Linearity2) of IPN
VOE Electrical Offset Voltage @ TA=25°C @IP=0
VOT Thermal drift of VOE @ 0..+70°
tr Response time @ 90% of IPN
±4
± 0.8
± 50
±100
<140
Large aperture
Good performances in harsh
EMC environment
% High isolation between primary
% and secondary circuits
mV Easy to mount
mV Bipolar
mS No insertion losses
General data
TA Ambient operating temperature
TS Ambient storage temperature
m Mass
Standard
Notes: 1) Between primary and secondary
2) Excludes the electrical offset
LEM Components
0..+70
-25..+85
140
TBD
Applications
DC leakage current
°C measurement
°C Differential current
g measurement in DC applica-
tions
Low DC current measurement
Options on request
DIN mounting
020521/0
www.lem.com



LEM DF0.1-C10
Dimensions DF-C10 (unit : mm, 1mm = 0.0394 inch)
18 10
25
55
4.2
70
Secondary terminals
Terminal 1 : Supply voltage +12...+15VDC
Terminal 2 : Supply voltage -12...-15VDC
Terminal 3 : Voltage output Vs
Terminal 4 : 0V
Mechanical characteristics
General tolerance
± 1 mm
Primary aperture
25 mm
Secondary connection
Finger safe terminals
Panel mounting
2 holes 4.2mm
(Distance between holes
38 mm x 55mm)
Remarks
The temperature of the primary bar can not exceed 90°C.
Output Voltage / Primary Current
20VDC
16VDC
VOUT (V)
10VDC
-IPmax IPN
IPN IPmax IP(A)
-10VDC
-16VDC
-20VDC
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)