MPU200 Factor Correction Datasheet

MPU200 Datasheet, PDF, Equivalent


Part Number

MPU200

Description

Power Factor Correction

Manufacture

Power-One

Total Page 6 Pages
Datasheet
Download MPU200 Datasheet


MPU200
MPU200/MDU200 Series Data Sheet
Features
• RoHS lead free solder and lead solder exempted products
are available
• Power Factor Correction (PFC) meets EN61000-3-2
• Same size, airflow, and construction as MPU150/MDU150
with over 33% more power
• Single-wire current sense on quad model outputs V1 and V2
• Remote sense on quad model outputs V1 and V2
• Current share and N+1 redundancy (standard on all models)
• Overtemperature, overload, and overvoltage protection
• Available with SAE mountings
• MDU200 models have 48VDC input
Description
The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products
incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series, 200W
of continuous output power is provided with single or multiple output units suited for distributed power or central power applications.
The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital circuitry.
Power-One's dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature
remote sense on outputs V1 and V2 to provide independent compensation of output cable losses.
Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote
inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch.
The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 volt DC input.
www.DataSheet4U.com
AC Input, Single-Output Model Selection
MODEL
MPU200-1012
MPU200-1024
MPU200-1048
OUTPUT
VOLTAGE
12V
24V
48V
ADJUSTMENT
RANGE
11.6V to 16V
22.8V to 29.2V
45V to 56V
MAXIMUM OUTPUT
CURRENT (NOTE 2)
17.0A
8.35A
4.2A
200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
PEAK OUTPUT
CURRENT (NOTE 2)
19.0A
9.4A
4.7A
LINE
REGULATION
0.1%
0.1%
0.1%
LOAD
REGULATION
1%
1%
1%
RIPPLE & NOISE
%p-p (NOTE 3)
1%
1%
1%
INITIAL SETTING
ACCURACY
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
AC Input, Multiple-Output Model Selection
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
+5V
5.0V to 5.5V
30A (Note 4)
0.4%
1%
MPU200-4530
+3.3V
12V
3.15V to 3.60V
10.8V to 13.2V
15A (Note 4)
8A (Note 5)
0.6%
0.4%
1.5%
10%
12V 10.8V to 13.2V 4A (Note 5)
0.4%
10%
NOTES: 1) This product is not rated for convection applications.
2) Output currents ratings are expressed with 300 LFM forced air.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Total current for V1 and V2 is not to exceed 35A.
5) Total power on V3 and V4 is not to exceed 100W.
RIPPLE & NOISE
%Pk-Pk (NOTE 3)
1%
1.5%
1%
1%
INITIAL SETTING
ACCURACY
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.60V to 12.40V
Ordering Information:
OPTIONS
Metric Mounting
Isolation Diode
RoHS lead solder exemption
RoHS compliant for all 6 substances
SUFFIXES TO ADD TO PART NUMBER
Add “M” as a suffix to the model number to order chassis with
M3 x 0.7 mounting inserts. Consult factory for availability.
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed.
Consult factory for availability.
No RoHS suffix character required.
Add “G” as the last character of the part number.
JUL 14, 2006 revised to JUL 24, 2006
Page 1 of 6
www.power-one.com

MPU200
MPU200/MDU200 Series Data Sheet
DC Input, Single Output Model Selection
200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1)
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT
LINE
RANGE
CURRENT (NOTE 2) CURRENT (NOTE 2) REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 3)
MDU200-1012G
MDU200-1024G
(NOTE 4)
MDU200-1048G
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
17.0A
8.35A
4.2A
19.0A
9.4A
4.7A
0.1%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
Isolation Diode Option - Offered on single-output models. Add “D” at the end of the part number if an isolation diode is needed.
INITIAL SETTING
ACCURACY
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
MPU200 Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
After last AC line peak at 200 watts
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
Per EN61000-3-2.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Switching frequency of Power Factor Correction circuit.
MIN
85
47
15
0.95
100
65
NOM
60
MAX
264
63
4.0
35
120
90
UNITS
VAC
Hz
ms
ARMS
APK
W/VA
kHz
MDU200 Input Specifications
PARAMETER
Input Voltage - DC
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
CONDITIONS/DESCRIPTION
Continuous input range.
Lowest DC input voltage that regulation is maintained with full rated loads.
At 200 watts, over DC input range.
36 VDC at full rated load.
Non-user serviceable internally located AC input line fuse.
Consult factory.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
MIN
NOM
MAX UNITS
36 75 VDC
34 VDC
15 ms
8.35
ARMS
100 kHz
70
NOTES:1) This product is not rated for convection applications.
2) Output currents ratings are expressed with 300 LFM forced air.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Derating is required on output voltages above 27VDC. Consult factory.
JUL 14, 2006 revised to JUL 24, 2006
Page 2 of 6
www.power-one.com


Features MPU200/MDU200 Series Data Sheet Feature s • • • • • • • • • R oHS lead free solder and lead solder ex empted products are available Power Fac tor Correction (PFC) meets EN61000-3-2 Same size, airflow, and construction as MPU150/MDU150 with over 33% more power Single-wire current sense on quad mode l outputs V1 and V2 Remote sense on qua d model outputs V1 and V2 Current share and N+1 redundancy (standard on all mo dels) Overtemperature, overload, and ov ervoltage protection Available with SAE mountings MDU200 models have 48VDC inp ut Description The MPU200/MDU200 Serie s is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products incorporate Power Factor Correction (PFC) with a low-profile pac kage designed to meet 1U height constra ints. In this series, 200W of continuou s output power is provided with single or multiple output units suited for dis tributed power or central power applica tions. The series provides high current +3.3V and +5V on a single platform to sup.
Keywords MPU200, datasheet, pdf, Power-One, Power, Factor, Correction, PU200, U200, 200, MPU20, MPU2, MPU, Equivalent, stock, pinout, distributor, price, schematic, inventory, databook, Electronic, Components, Parameters, parts, cross reference, chip, Semiconductor, circuit, Electric, manual, substitute




@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)