Synthesizer. MASYVS0061-1066 Datasheet

MASYVS0061-1066 Synthesizer. Datasheet pdf. Equivalent

Part MASYVS0061-1066
Description Synthesizer
Feature www.DataSheet4U.com Synthesizer , SMT 1046 — 1085 MHz, 200 kHz Features ♦ Fully Integrated VCO, PLL.
Manufacture Tyco Electronics
Datasheet
Download MASYVS0061-1066 Datasheet



MASYVS0061-1066
www.DataSheet4U.com
Synthesizer , SMT
1046 — 1085 MHz, 200 kHz
Features
Fully Integrated VCO, PLL, Loop Filter
High Performance, Low Cost
Miniature SMT Package (LSM6)
Description
This synthesizer design integrates a high performance VCO, PLL,
IC and discrete loop filter in a surface mount package. This SMT
package provides electrical shielding, easy PCB assembly and re-
peatable performance. The synthesizer is designed for use in wire-
less base stations.
M/A-COM synthesizers are manufactured in an ISO9001 certified
facility, incorporating surface mount assembly and automated elec-
trical testing. This ensures consistent electrical performance and
quality over volume production quantities.
MASYVS0061-1066
Rev: E
Electrical Specifications1:
TA = +25°C, Z0 = 50 Ohms, Fref = 10MHz, Vcc1 = 5V, Vcc2 = 3.3V.
Parameter
Frequency Range
RF Output Power
Phase Noise
Test Conditions
Over Top 2
Over Top 2
SSB at 600 kHz offset from carrier
SSB at 800 kHz offset from carrier
SSB at 1800 kHz offset from carrier
SSB at 6000 kHz offset from carrier
Harmonic Suppression
Spurious Suppression
(Non-Harmonic)
Phase comparison frequency ( ± 200 kHz)
± 400 kHz
± 600 kHz
± 800 kHz
Reference breakthrough ( ± 10 MHz)
Frequency Lock Time
Phase Error (rms)
Over Fout , Measured to within ± 4 degrees
Measured over 577υs time slot
Phase Error (peak)
Measured over 577υs time slot
VCO Supply Current (ICC1)
PLL Supply Current (ICC2)
VCO Power Supply (VCC1)
PLL Power Supply (VCC2)
Recommended operating condition
Recommended operating condition
Recommended operating condition
Recommended operating condition
Units
MHz
dBm
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc
dBc
dBc
dBc
dBc
dBc
υs
Degree
Degree
mA
mA
V
V
Min
1046
+2.5
+4.75
+3.1
Typ
-145
-151
-153
-160
-33
-85
-87
-93
-97
-100
0.6
1.7
47
13
+5.00
+3.3
Max
1085
+7.5
-144
-148
-151
-157
-20
-79
-84
-90
-95
-97
450
1.0
4
55
15
+5.25
+3.5
1. All specification limits are indicated values @ +25 ºC and apply over Fout unless otherwise stated.
2. Top = -40ºC to +85ºC operating temperature.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.



MASYVS0061-1066
Synthesizer , SMT
1046 — 1085 MHz, 200 kHz
Electrical Specifications1: (cont’d)
MASYVS0061-1066
Parameter
Step Size (F)
Reference Frequency (FR)
PLL Programming
PLL Lock Monitor Output
Test Conditions
Units
Min
Typ
Recommended operating limit
kHz
200
1.0 V pp ± 0.2V square wave with input filter
MHz
10
3-wire serial CMOS IAW ADF4113, Charge Pump 5 mA
Logic high = VCC2 x 0.8 Min and Logic low = VCC2 x 0.2 Max
Locked = VCC2 - 0.4 Min , Unlocked = 0.4V Max
Max
100
Pin Configuration
Pin No.
1
2
3
4
5
6
7
Function
VCC1
GND
REF I/P
GND
VCC2
GND
RF O/P
Pin No.
8
9
10
11
12
13
14
Function
GND
Lock Detect
Clock
Data
Load Enable
GND
GND
Functional Block Diagram
Absolute Maximum Ratings
TA = +25°C
Parameter
Absolute Maximum
VCO Supply Voltage (VCC1)
PLL Supply Voltage (VCC1)
Reference Frequency Level
-0.3V to 6.5 V
-0.3V to 6.5 V
-0.3V to 6.5 V
Data, Clock, Strobe
Voltages
Operating Temperature
Storage Temperature
-0.3V to Vcc + 0.3 V
-40°C to +85°C
-45°C to +120°C
Solder Assembly
Temperature
See App Note M2032
1. Operation of this device above any one of these parameters
may cause permanent damage.
2. Static sensitive, observe appropriate handling precautions.
Environmental Specifications
Devices are designed to function after exposure to the
shock, vibration, thermal shock and moisture conditions
typically encountered in base station and other infra-
structure environments.
1. The diagram above shows a typical application.
2. The Reference input and RF output are internally AC cou-
pled.
3. The diagram applies when digital lock detect is selected. For
analog open-drain mode, a filter is required. See AN3003 for
design information.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
Ordering Information
Part Number
MASYVS0061-1066 B
MASYVS0061-1066 T
MASYVS0061-1066 R
Package
Bulk Packaging
Tape and Reel (300/Reel) 1
Reverse Tape and Reel
(300/Reel) 1
1. See application note M513.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.