Military/Aerospace Relays. FCA-210 Datasheet

FCA-210 Relays. Datasheet pdf. Equivalent

Part FCA-210
Description Mid-Range Military/Aerospace Relays
Feature SERIES www.DataSheet4U.com FCA-210 Tyco Electronics Mid-Range Military/Aerospace Relays 10 AMPERE.
Manufacture ETC
Datasheet
Download FCA-210 Datasheet




FCA-210
SERIES
www.DataSheet4U.comFCA-210
Tyco Electronics Mid-Range Military/Aerospace Relays
10 AMPERES, DPDT
q HERMETICALLY SEALED
q ALL WELDED CONSTRUCTION
q BALANCED FORCE
q PERMANENT MAGNET DRIVE
q CONTACTS: SILVER CADMIUM
OXIDE WITH GOLD PLATING
q COILS FOR DC, 50 TO 400Hz AND 400Hz AC
q WEIGHT 1.6 OUNCES MAX. (45.4 GRAMS)
QQPuaLlifiAedPtoPMRILO-R-V83E53D6
The Series FCA-210 relay is a polarized single-side stable design, where the flux from a permanent
magnet provides the armature holding force in the deactivated state, and its flux path is switched
and combined with the coil flux in the operated state. This results in appreciably increased contact
pressure in both states over that of a spring return nonpolar design. We also manufacture other
versions of this relay:
FCA-410: 10 AMPERE 4PDT RELAY
FCA-610: 10 AMPERE 6 PDT RELAY
AVAILABLE
FCA-215: 15 AMPERE DPDT RELAY, HAS THE SAME SPECIFICATIONS AS THE FCA-210
EXCEPT IS RATED AT 15 AMPS.
CONTACT RATING-AMPERES
Ratings Are Continuous Duty
TYPE OF
LOAD
LIFE (MIN.)
CYCLES X 103
28 VDC
Resistive
Inductive
Motor
Lamp
100
20
100
100
10
8
4
2
115VAC
400Hz
10
8
4
2
115/200VAC 30
400 Hz 60Hz *
10 2.5
8 2.5
4 2.0
21
* 60 Hz LOADS RATED FOR 10,000 OPERATIONS
OVERLOAD CURRENT 40 AMPS DC, 60AMPS 400Hz
RUPTURE CURRENT 50 AMPS DC, 80 AMPS 400Hz
CONTACT MAKE BOUNCE 1 MILLISECOND AT NOMINAL VOLTAGE
MAX. CONTACT DROP AT 10 AMPS: INITIAL 0.100 VOLTS.
END OF LIFE 0.125 VOLTS
8



FCA-210
SERIES
FCA-210
Tyco Electronics Mid-Range Military/Aerospace Relays
10 AMPERES, DPDT
COIL DATA
COIL
CODE
NOMINAL
VOLTAGES
FREQ.
Hz
OVER TEMPERATURE RANGE
DC RES.
PICKUP OR DROPOUT OR MUST HOLD
AC AMPS (B) BELOW VOLTS ABOVE VOLTS VOLTAGE (C)
1
2
3
4 (A)
5
6
7
8
9
6
12
28
28
48
28
28
115
115
DC
DC
DC
DC
DC
400Hz
50/400Hz
400 Hz
50/400Hz
20
80
320
320
920
180 mA
100 mA
40 mA
30 mA
4.5
9.0
18.0
18.0
32.0
22.0
22.0
90.0
95.0
0.3
0.75
1.5
1.5
2.5
1.25
1.25
5.0
5.0
2.5
4.5
7.0
7.0
14.0
10.0
10.0
40.0
40.0
A. CODE 4 COILS HAVE BACK EMF SUPPRESSION D. MAX. OVERVOLTAGE: 6 & 12 VDC COILS 120% OF
TO 42 VOLTS MAX.
NOMINAL; ALL OTHERS 110% OF NOMINAL.
B. DC COIL RESISTANCE ± 10% AT 25˚C;
E. COILS AVAILABLE FOR OTHER VOLTAGES AND
AC COIL MAX. CURRENT AT NOMINAL VOLTAGE. FOR AC 50/60HZ.
C. RELAY WILL STAY IN PICKED-UP STATE DOWN TO
MUST HOLD VOLTAGES SHOWN.
NOTE: Only DC Coil Models are QPL Approved.
GENERAL SPECIFICATIONS
TEMPERATURE RATING:
-70˚C TO + 125˚C
ALTITUDE:
300,000 FEET
SHOCK:*
Z, Y, & X ENCLOSURES
200 g FOR 6 mS
W & M ENCLOSURES (STUD MTG.)
100 g FOR 6 mS
VIBRATION, SINUSOIDAL:*
Z, Y, & X ENCLOSURES
30 g 33-3000Hz
W & M ENCLOSURES (STUD MTG.)
20 g 33-3000Hz
VIBRATION, RANDOM: *
Z, Y, & X ENCLOSURES
0.4 g2/Hz 50-2000Hz
W & M ENCLOSURES (STUD MTG.)
0.2 g2/Hz 50-2000Hz
DIELECTRIC STRENGTH
ALL CIRCUITS TO GROUND AND
AT SEA LEVEL:
CIRCUIT TO CIRCUIT.
1250 V rms
COIL TO GROUND
1000 V rms
DIELECTRIC STRENGTH
AT 80,000 FEET:
350 V rms
INSULATION RESISTANCE:
INITIAL (500 VDC)
100 MMINIMUM
AFTER LIFE OR ENVIRONMENTAL TESTS 50 MMINIMUM
OPERATE TIME AT NOMINAL VOLTAGE: DC RELAYS
10 ms OR LESS
AC RELAYS
15 ms OR LESS
RELEASE TIME AT NOMINAL VOLTAGE: DC RELAYS
10 ms OR LESS
AC RELAYS
50 ms OR LESS
* Max. contact opening under vibration or shock 10 microseconds
9







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)