DatasheetsPDF.com

- 260W. LPQ142-CF Datasheet

DatasheetsPDF.com

- 260W. LPQ142-CF Datasheet






LPQ142-CF 260W. Datasheet pdf. Equivalent




LPQ142-CF 260W. Datasheet pdf. Equivalent





Part

LPQ142-CF

Description

AC-DC / 136W - 260W



Feature


Embedded Power for Business-Critical Con tinuity LPQ142 Series 145 Watts Total Power: Input Voltage: # of Output s: 110 - 145 Watts 85-264 VAC 120-300 VDC Quad Rev. 11.17.08_103 LPQ142 Seri es  of 3 Electrical Specifications Sp ecial Features • • • • • • • • • • • Active power factor correction IEC EN61000-3-2 compliance Adjustable outputs on.
Manufacture

Emerson

Datasheet
Download LPQ142-CF Datasheet


Emerson LPQ142-CF

LPQ142-CF; 1, 3 & 4 Remote sense on main output Si ngle wire current sharing Power fail an d remote inhibit Built-in EMI filter Lo w output ripple Overvoltage protection Overload protection Thermal overload pr otection Adjustable floating 4th output Optional cover (-C suffix) Optional fa n cover (-CF suffix) Input Input ra­n ge: Frequency: Inrush current: Efficien cy: EMI filter: 85-.


Emerson LPQ142-CF

264 VAC; 120-300 VDC 47-67 Hz 38 A max, cold start @ 25°C 75% typical at full load Meets FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B co nducted VDE 0878 PT3 Class B conducted 0.99 typical 1.0 mA @ 50/60 Hz, 264 VAC input Power Factor: Safety ground lea kage current: Output Maximum power: 80 W convection (60 W with cover -C) 145 W with 30 CFM force.


Emerson LPQ142-CF

d air (100 W with cover -C) 3.3 - 5.5V o n main; -12 - 15V on 3rd output 3.3 - 2 5 V on 4th output 20 ms @175 W load at nominal line  hort circuit protection on all outputs. Case overload protected @ S 110-145% above peak rating Tracks outputs 1, 3 & 4; 10 to 35% Adjustment range: Safety • • • • • • VDE UL CB CSA CE NEMKO 60950 609 50 Certificate and report 6095.

Part

LPQ142-CF

Description

AC-DC / 136W - 260W



Feature


Embedded Power for Business-Critical Con tinuity LPQ142 Series 145 Watts Total Power: Input Voltage: # of Output s: 110 - 145 Watts 85-264 VAC 120-300 VDC Quad Rev. 11.17.08_103 LPQ142 Seri es  of 3 Electrical Specifications Sp ecial Features • • • • • • • • • • • Active power factor correction IEC EN61000-3-2 compliance Adjustable outputs on.
Manufacture

Emerson

Datasheet
Download LPQ142-CF Datasheet




 LPQ142-CF
Embedded Power for
Business-Critical Continuity
LPQ142 Series
145 Watts
Total Power:
Input Voltage:
# of Outputs:
110 - 145 Watts
85-264 VAC
120-300 VDC
Quad
Rev. 11.17.08_103
LPQ142 Series
 of 3
Special Features
• Active power factor correction
• IEC EN61000-3-2 compliance
• Adjustable outputs on 1, 3 & 4
Remote sense on main output
• Single wire current sharing
• Power fail and remote inhibit
• Built-in EMI filter
• Low output ripple
• Overvoltage protection
• Overload protection
• Thermal overload protection
• Adjustable floating 4th output
• Optional cover (-C suffix)
• Optional fan cover (-CF suffix)
Safety
VDE
UL
CB
CSA
CE
NEMKO
60950
60950
Certificate and report
60950
Mark (LVD)
EN 60950/EMKO-TUE
Electrical Specifications
Input
Input ra­nge:
Frequency:
Inrush current:
Efficiency:
EMI filter:
Power Factor:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection:
85-264 VAC; 120-300 VDC
47-67 Hz
38 A max, cold start @ 25°C
75% typical at full load
Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
0.99 typical
1.0 mA @ 50/60 Hz, 264 VAC input
80 W convection (60 W with cover -C)
145 W with 30 CFM forced air
(100 W with cover -C)
3.3 - 5.5V on main; -12 - 15V on 3rd output
3.3 - 25 V on 4th output
20 ms @175 W load at nominal line
Short circuit protection on all outputs. Case overload protected @
110-145% above peak rating
Tracks outputs 1, 3 & 4; 10 to 35%




 LPQ142-CF
Embedded Power for
Business-Critical Continuity
Logic Control
AC power failure:
Remote inhibit:
Remote sense:
DC - OK:
TTL logic signal goes high 100 - 500 msec after V1 output; It goes low
at least 4 msec before loss of regulation
Requires contact closure to inhibit outputs
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
TTL logic signal goes high after main output is in regulation. It goes low
when there is a loss of regulation
Environmental Specifications
Operating temperature: 0° to 50 °C ambient. Derate each output 2.5% per degree from 50° to
70 °C (except for -C version).
Storage temperature: -40 °C to +85 °C
Temperature coefficient: ±0.4% per °C
Electromagnetic
susceptibility:
Designed to meet IE61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3
Humidity:
Operating; non-condensing 5% to 95%
Vibration:
MTBF demonstrated:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major
resonances 0.75G peak 5Hz to 500Hz, operational
>550,000 hours at full load and 25°C ambient conditions
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load
with 30CFM
Forced Air
Peak Load 1 Regulation 2
Ripple P/P
(PARD)3
LPQ142 5 V (3.3 - 5.5 V) 0 A
12 A
25 A
27 A
±2%
50 mV
12 V
0A
5A
6 A 9 A ±3% 120 mV
-12V (-12 -15 V) 0 A
1A
1.5 A
2 A ±3%
<1%
±3.3-25 V
0.5 A
1.5 A
4.5 A
5 A ±3% <50mV or 1%
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. 4th output adjustable 3.3-25 V factory set at 5 V.
5. *Minimum loads are required when output set below 5 Volts
6. Remote inhibit resets OVP latch
Note: -C suffix added to the model number indicates cover option.
-CF suffix added to the model number indicates fan cover option.
Rev. 11.17.08_103
LPQ142 Series
 of 3
Pin Assignments
SK1 PIN 1
PIN 3
Ground
Neutral
PIN 5
SK2 PIN 1
Line
+12 V
PIN 2
PIN 3
PIN 4
Common
-12 V
Common
PIN 5
PIN 6
SK4 TB-1
TB-2
SK6 PIN 1
+5 V to +25 V (float)
Common (float)
Common
+5 V
N/C
PIN 2
PIN 3
PIN 4
DC OK
N/C
V1 SWP
PIN 5
PIN 6
Common
+V1 sense
PIN 7
PIN 8
PIN 9
Sense common
+ inhibit
- inhibit
PIN 10
Power fail
Mating Connectors
(SK1) AC Input:
Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Aux DC Output: Molex 09-50-8061 (USA)
Molex 09-91-0600 (UK)
PINS: 08-58-0111
(SK6) Control Signals: Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
(SK4) Main output: Molex BB-19141-0058
Emerson Network Power connector kit #70-841-017,
includes al of the above.




 LPQ142-CF
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
L
SK1 N
GND
-CF option
29.1
M3
(2X) 6.4
#6-32
161.5
171.5
V1 Adj
MAIN
OUTPUT
V4 Adj - Course
V4 Adj - Fine
SK2
SK6
V4-
V4+
COMM
-12V OUT
COMM
+12V OUT
M3
(3X) 19.1
1.5
(38.1)
#6-32
4.00
(101.6)
(4X) 63.5
(2X) 119.6
(2X) 139.7
7.0
(177.8)
M3 (8 places)
#6-32 (8 places)
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”.
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting screw maximum insertion depth is 0.12”.
5. Warranty: 2 year
6. Weight: 1.63 lb / 0.74 kg
Rev. 11.17.08_103
­Americas
5810 Van Allen Way
LPQ142 Series
 of 3
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.






Recommended third-party LPQ142-CF Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)