Emerson MP6

MP6; Embedded Power for Business-Critical Con tinuity MP Series 400 - 1200 Watts Tot al Power: 400 - 1200 Watts Input Volta ge: 85 - 264 VAC 120 - 350 VDC # of Outputs: Up to 21 Rev. 8.31.09_89 MP Series  of 8 Special Features •  C urrent share on all outputs with rating s of 10 A or greater • Remote sense on all outputs with ratings greater tha n 2 A • Overload prot.


Emerson MP6

ection on all outputs • Voltage adjus tment on all outputs • Margining on all single output modules • Input OK signal and status indicator LED • G lobal DC OK signal and status indicator LED • Global and individual module inhibits/ enable • 2 year warranty Forced air cooling, field replaceab le fan • Isolated 5 V bias voltage Power factor correction • EN610 00-3-2 harmonic distortion compliance CISPR 22, EN55022 Curve B conducted / radiated EMI • European CE Mark re quirements • Optional VME timing and system DC OK module • Customer-prov ided air option • Additional 200 W o utput @ high line (180-264 VAC) • L ow leakage option for medical applicati ons • EN61000 immunity standards • Standard modification flexibilit.



Part

MP6

Description

AC-DC / Configurable

Manufacture

Emerson

Datasheet
Download MP6 Datasheet




 MP6
Embedded Power for
Business-Critical Continuity
MP Series
400 - 1200 Watts
Total Power: 400 - 1200 Watts
Input Voltage: 85 - 264 VAC
120 - 350 VDC
# of Outputs: Up to 21
Special Features
• Current share on all outputs with
ratings of 10 A or greater
• Remote sense on all outputs with
ratings greater than 2 A
• Overload protection on all outputs
• Voltage adjustment on all outputs
• Margining on all single output modules
• Input OK signal and status indicator
LED
• Global DC OK signal and status
indicator LED
• Global and individual module inhibits/
enable
• 2 year warranty
• Forced air cooling, field replaceable fan
• Isolated 5 V bias voltage
• Power factor correction
• EN61000-3-2 harmonic distortion
compliance
• CISPR 22, EN55022 Curve B conducted
/ radiated EMI
• European CE Mark requirements
• Optional VME timing and system DC
OK module
• Customer-provided air option
• Additional 200 W output @ high line
(180-264 VAC)
• Low leakage option for medical
applications
• EN61000 immunity standards
• Standard modification flexibility
(consult factory)
Low noise fan
Fan fail signal
Module enable
Outputs down to 0.5V
Safety
UL UL1950
CSA CSA22.2 No. 234 Level 5
IEC IEC950, Class 1
VDE EN60950,
BABT Compliance to EN 60950,
BS 7002
CB Certificate and report
CE Mark
Rev. 8.31.09_89
MP Series
 of 8
Electrical Specifications
Input
Input ra­nge:
Frequency:
85 - 264 Vac
120 - 350 Vdc
47 - 440 Hz
Inrush current:
40 A peak max. (soft start)
Efficiency:
70 - 80% typ. @ full case load
Power Factor:
0.99 typ. meets EN61000-3-2
Turn-on time:
EMI filter standard:
AC on 1.5 sec typ.
inhibit/enable 150 ms typ.
CISPR 22/EN55022 Level “B”
EMI filter (low leakage
option):
CISPR 22/EN55022 Level “A”
Leakage current standard: 2.0 mA max. @240 Vac
Leakage current (low leak- 300µA max. @ 240 Vac
age option):
Radiated EMI:
Holdover storage:
CISPR 22/EN55022 Level “B”
20 ms minimum (independent of input Vac)
AC OK:
Harmonic distortion:
Isolation:
>5 ms early warning min. before outputs lose regulation
Full cycle ride thru (50 Hz)
Meets EN61000-3-2
Meets EN60950
Global Inhibit/Enable:
Input fuse (internal):
TTL, Logic “1” and Logic “0”
MP4: 10 A; MP6: 15 A; MP8: 20 A; MP1: 20 A
Warranty:
2 years





 MP6
Embedded Power for
Business-Critical Continuity
Rev. 8.31.09_89
MP Series
 of 8
Output
Adjustment range:
± 10% minimum all outputs
Margining:
± 4 - 6% nominal1
Overall regulation:
0.4% or 20mV max.
(36 W modules 4% maximum)
Ripple:
RMS: 0.1% or 10mV, whichever is greater
Pk-Pk: 1.0% or 50mV, whichever is greater
Bandwidth limited to 20 MHz
Dynamic response:
< 2% or 100 mV, with 25% load step
Recovery time:
To within 1% in < 300 µsec
Overcurrent
protection:**
Single output module & main output of
dual output module
105-120% of rated output current.
Aux output of dual output module 105-
140% of rated output current
Short-circuit protection: Protected for continuous short-circuit
Recovery auto upon removal of short
Overvoltage protection:
(measured at sense
connection)
Single output module: 2-5.5 V 122-134% ; 6-60 V 100-120%
Output (cont.)
Thermal protection:
Remote sense:
Single wire parallel:
DC OK:
Minimum load:
Housekeeping bias
voltage:
Module inhibit:
Switching frequency:
Output/Output isolation:
VME signal option board:
Hold-up module (HUP):
All outputs disabled when internal temp
exceeds safe operating range. > 5ms
warning (AC OK signal) before shutdown
Up to 0.5 V total drop (not avbl on triple
output module)
Current share to within 2% of total rated
current2
-2% to -8% of nominal for any monitored
output2
Not required on single or triple output. 10%
required on main of dual output3
5 Vdc @ 1.0 A max. present whenever AC
input is applied
TTL, isolated, singles and dual (both
outputs) only
250k Hz
>1 Megohm
POR signal & quad external DC OK
1-slot module providing additional 34mSec
(60mSec total); hold-up @ 600 W loading.
Dual output module: 2-6 V 122-134% ; 8-28 V 110-120%
Triple output module: No overvoltage protection provided.
Recycle AC input voltage to reset OVP
circuit
Reverse voltage protection: 100% of rated output current
Environmental Specifications
1. Single output modules only.
2. Single and main of dual output modules only
3. Contact factory for optional preload if required
Field Demonstrated MTBF: > 550,000 hours at full load, 220 Vac and
25 °C ambient conditions
Operating temperature:
Shock/Vibration:
Humidity:
Storage temperature:
Temperature coefficient:
Cooling:
-20 °C to 50 °C (start @ 0 °C)
(derate each output linearly to 50% at 70 °C)
(-20 °C to 40 °C max. with rear air option)
Mil-Hdbk 810E
95% non-condensing
-40 °C to 85 °C
0.02% per °C
Internal DC fan or customer provided air (option)
Output Module Line-up
Module Type
Output
Max output power
Max output current
Volts
Standard voltage increments
Remote sense on outputs
Remote margin/V-Program
Module Inhibit (isolated)
Single wire active current share
Over voltage / over current protection
Minimum load required
Slots occupied in any MP case
Single
1
210 W
35 A
2-60 V
25
Yes
Yes
Yes
Yes
Yes
No
1
Single
1
360 W
60 A
2-60 V
25
Yes
Yes
Yes
Yes
Yes
No
2
Single
600 W
120 A
2-60 V
25
Yes
Yes
Yes
Yes
Yes
No
3
Dual
2
144 W
10 A
2-28 V
19
Yes, both
No
--
Yes, main only
Yes
Yes (10%) main only
1
Triple
3
36 W
2A
2-28V
18
No
No
--
--
Over current
No
1