Magnetic Display. MA502 Datasheet

MA502 Display. Datasheet pdf. Equivalent

Part MA502
Description Magnetic Display
Feature Magnetic Display MA502 This display serves to interpret information from the incremental MS500 magne.
Manufacture ETC
Datasheet
Download MA502 Datasheet



MA502
Magnetic Display MA502
This display serves to interpret information from the
incremental MS500 magnetic sensor for distance and angle
measurement. The display parameters are comprehensive
and individually programmable. Optionally equipped with
serial interface and integrated power unit.
96
89.5 42.5
Features
high-contrast 12-digit LCD, dot matrix
integrated translation module for length and angle
measurement
incremental/reset function
input for reference switch
programmable last value memory
direct input of reference/offset value
option: 2 measuring channels
Feature
Design
Operating voltage
Reference connection
Interface / protocol
Switching output
Input
Software
Magnetic sensor
Display / display range
Connection
Travel speed
Resolution
Repeat accuracy
System accuracy
Protection class, test mark
Signal input
Temperature range
Type of protection
Humidity
Ordering data Technical data
AEG panel-mount housing, cutout 92 x 45 mm
TG bench-top housing
Additional information
standard, Noryl GFN 2 SE 1, as snap-in module
aluminium profile, black anodized
B4 24 V DC ±20%
1 230 V AC ±10%
2 115 V AC ±10%
standard
CRM with connection
RO without (only bench-top housing)
standard
DXX/XX
S1/00
without
RS232 with standard protocol
standard
others on request
ESO without
SM with
standard
only for XX/XX interface
F1 one channel
2 two channels
standard
GS
SW01
for two channels
standard
MS500
12-digit LCD dot matrix
sensor: Mini-DIN
max. 5 m/s (of the magnetic sensor)
in mm 0.01/0.1/1/10
± 1 digit
± (0.05 + 0.01 x L)mm [L in m]
3 according to IEC 801
reference switch
working temperature: 0 ... +50 °C
IP 40 acc. to DIN 40050 for whole unit
95 % rH
incremental
-9 999 999 … 9 999 999 + sign + units
supply: 9-pin screwed terminal strip (EG)
with 0.1–2.0 mm band/sensor gap
in inch 0.001/0.01/0.1/1, angles 0°–90°–0° / 0°–360°
at TU = 20 °C
CE
storage temperature: -20 ... +80 °C
IP 60 acc. to DIN 40050 for control panel inclusion
condensation not permitted
Your order:
MA502 – – – – – – –
ABCDE FG