Feature G3MC-101P; G3MC Solid State Relays Reinforced Insulation Models Added to Compact, Thin-profile Series of SSRs f.
Manufacture Omron Electronics
Datasheet
Download G3MC-101P Datasheet




Omron Electronics G3MC-101P
G3MC
Solid State Relays
Reinforced Insulation Models
Added to Compact,
Thin-profile Series of SSRs
for PCBs
• 4.5-mm thin design for high-density PCB applications.
• DC input and AC output for applicable load of 1A (at 40°C)
and 2A (at 25°C).
• Compact, thin-profile SSR of monoblock construction with
an all-in-one lead frame incorporates a PCB, terminals and
heat sink
RoHS Compliant
Refer to "Solid State Relays Common Precautions".
Model Number Legend
G3MC-@@@@@-@@
———— —
1 2 34 5
List of Models
1. Rated Load Power Supply Voltage
1: Maximum operating voltage higher than
100 V, lower than 200 V
2: Maximum operating voltage higher than
200 V, lower than 300 V
2. Rated Load Current
01: 1 A
02: 2 A
3. Terminal Type
P: PCB terminals
4. Zero Cross Function
Blank: Equipped with zero cross function
L : Not equipped with zero cross
function
5. Certification
Blank: Certified by UL and CSA (standard
models)
-VD : Certified by UL, CSA and EN
-VD-1: Certified by UL, CSA and EN
(reinforced insulation models)
G
3
M
C
Isolation
Phototriac
Zero cross
function
Yes
No
Yes
No
Yes
No
Indicator
No
Snubber
circuit
Yes
Rated output load Rated input voltage
1 A at 100 to 120 VAC
1 A at 100 to 240 VAC
2 A at 100 to 240 VAC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
Note. Refer to the "List of Certified Models" for UL, CSA, and EN approved models.
Model
G3MC-101P
G3MC-101P-VD
G3MC-101PL
G3MC-101PL-VD
G3MC-201P
G3MC-201P-VD
G3MC-201P-VD-1
G3MC-201PL
G3MC-201PL-VD
G3MC-201PL-VD-1
G3MC-202P
G3MC-202P-VD
G3MC-202P-VD-1
G3MC-202PL
G3MC-202PL-VD
G3MC-202PL-VD-1
Minimun
packing unit
100 pcs
1



Omron Electronics G3MC-101P
G3MC
Solid State Relays
Ratings (at an Ambient Temperature of 25•C)
Input (Each model has 5-VDC, 12-VDC, and 24-VDC input versions.)
Rated voltage
5 VDC
12 VDC
24 VDC
Output
Operating voltage
4 to 6 VDC
9.6 to 14.4 VDC
19.2 to 28.8 VDC
Impedance Must operate voltage level Must release voltage level
300Ω ± 20%
4 VDC max.
800Ω ± 20%
9.6 VDC max.
1 VDC min.
1.6 kΩ ± 20%
19.2 VDC max.
Item
Applicable load
Model
Rated load voltage Load voltage range Load current Inrush current
G3MC-101P (-VD)
G3MC-101PL (-VD)
G3MC-201P (-VD) (-1)
G3MC-201PL (-VD) (-1)
100 to 120 VAC
50/60 Hz
100 to 240 VAC
50/60 Hz
75 to 132 VAC
50/60 Hz
75 to 264 VAC
50/60 Hz
0.1 to 1 A *
8A
(60 Hz, 1 cycle)
G3MC-202P (-VD) (-1)
G3MC-202PL (-VD) (-1)
100 to 240 VAC
50/60 Hz
75 to 264 VAC
50/60 Hz
0.1 to 2 A *
30 A
(60 Hz, 1 cycle)
* The load current varies depending on the ambient temperature. Refer to Load Current
vs. Ambient Temperature under Engineering Data.
Characteristics
Item
Model
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
G Dielectric strength
3 Vibration resistance
M Shock resistance
C Storage temperature
Ambient operating
temperature
Ambient operating
humidity
Weight
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202PL(-VD)(-1)
1/2 of load power source cycle +
1 ms max.
1 ms max.
1/2 of load power source cycle +
1 ms max.
1 ms max.
1/2 of load power source cycle + 1 ms max.
1.6 V (RMS) max.
1 mA max. (at 100 VAC)
1.5 mA max. (at 200 VAC)
1,000 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min between input and output (3,000 VAC, 50/60 Hz for 1 min for G3MC-@@@-VD-1)
10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
1,000 m/s2
-30•C to 100•C (with no icing or condensation)
-30•C to 80•C (with no icing or condensation)
45% to 85%RH
Approx. 2.5 g (Approx. 3.8 g for G3MC-202P(L)(-VD)(-1)
Engineering Data
Load Current vs. Ambient Temperature
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202PL(-VD)(-1)
1.2 2.5
1.0
2.0
0.8
1.5
0.6
1.0
0.4
0.5
0.2
0
?30 ?20
0
20 40 60 80 100
Ambient temperature (°C)
0
?40 ?20 0 20 25 40 60 80 100
Ambient temperature (°C)
2



Omron Electronics G3MC-101P
G3MC
Solid State Relays
One Cycle Surge Current: Non-repetitive Keep the inrush current to half the read value if it occurs repeatedly.
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202PL(-VD)(-1)
10 40
8
30
6
20
4
10
2
010 30 50 100 300 500 1,000
5,000
Energized time (ms)
0
10 30 50 100 300 500 1,000
5,000 10,000
Energized time (ms)
Dimensions
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-201PL(-VD)(-1)
24.5 max.
4.5 max.
13.5 max.
0.8
3.5
2.54 0.25
4-1.6
4-0.7
10.16 7.62
1.2
2.54
(Unit: mm)
PCB Dimensions
(Bottom View)
2.54 Four, 1.0-dia. holes
Terminal Arrangement/
Internal Connections
(Bottom View)
()4 3(+) 2 1
2.54
INPUT LOAD
G
3
M
C
G3MC-202P(-VD)(-1)
G3MC-202PL(-VD)(-1)
20.5 max.
24.5 max.
4.5 max.
PCB Dimensions
(Bottom View)
2.54 Four, 1.0-dia. holes
Terminal Arrangement/
Internal Connections
(Bottom View)
()4 3(+) 2 1
2.54 INPUT LOAD
0.8
3.5
2.54 0.25
4-1.6
4-0.7
10.16 7.62
1.2
2.54
Safety Precautions
Please refer to “Solid State Relays Common Precautions” for correct use.
Precautions for Correct Use
• The terminals are made of highly heat-conductive materials. Each
terminal must be soldered within 10 s at 260°C or within 5 s at
350°C.
• The SSR is of a thin-profile construction. To maintain the vibration
resistance of the SSR, make sure that the space between the SSR
and PCB is 0.1 mm maximum. Lifting of the PCB can be prevented
by setting the hole diameter of the PCBs on both sides slightly
smaller than the actual terminal dimension.
• Select the model without the zero-cross function when using the
Unit for phase control output.
• The casing works as a heat sink. When mounting two or more
Units closely, make sure that the Units are properly ventilated by
taking ambient temperature rises into consideration. If Units are
closely mounted and used in places with no ventilation, the load
current of each Unit must be 1/2 of the rated load current.
• Although LOAD is incorporated with snubber circuit, do not wiring
high voltage line and power line together with or in the same duct
as the SSR. Doing so may result in malfunction or damage due to
induction.
• The input circuit is not incorporated with reverse connection
protection circuit. Make sure to check the polarity when wiring.
• Connect the surge absorbers (varistors) in parallel at both ends of
the LOAD terminal when applying a surge voltage over 250 V peak
for G3MC-10@P(L)(-VD), and over 450V peak for
G3MC-20@P(L)(-VD)(-1).
INPUT
SSR
LOAD
Load
3