DatasheetsPDF.com

LM76

Texas Instruments
Part Number LM76
Manufacturer Texas Instruments
Description 12-Bit + Sign Digital Temperature Sensor and Thermal Window Comparator
Published Mar 11, 2020
Detailed Description LM76 www.ti.com SNIS109E – JANUARY 2000 – REVISED MARCH 2013 LM76 ±0.5°C, ±1°C, 12-Bit + Sign Digital Temperature Sen...
Datasheet PDF File LM76 PDF File

LM76
LM76



Overview
LM76 www.
ti.
com SNIS109E – JANUARY 2000 – REVISED MARCH 2013 LM76 ±0.
5°C, ±1°C, 12-Bit + Sign Digital Temperature Sensor and Thermal Window Comparator with Two-Wire Interface Check for Samples: LM76 FEATURES 1 •2 Window Comparison Simplifies Design of ACPI Compatible Temperature Monitoring and Control.
• Serial Bus Interface • Separate Open-Drain Outputs for Interrupt and Critical Temperature Shutdown • Shutdown Mode to Minimize Power Consumption • Up to 4 LM76s can be Connected to a Single Bus • 12-bit + Sign Output; Full-scale Reading of Over 127°C KEY SPECIFICATIONS • Supply Voltage 5.
0V • Supply Current – Operating – 250 µA (typ) – 450 µA (max) – Shutdown – 8 µA (max) • Temperature +25ºC ±0.
5ºC (max) – Accuracy – –10ºC to +45ºC ±10°C (max) – 70°C to 100°C ±1.
0°C (max) • Resolution 0.
0625°C APPLICATIONS • System Thermal Management • Personal Computers • Office Electronics • HVAC DESCRIPTION The LM76 is a digital temperature sensor and thermal window comparator with an I2C Serial Bus interface with an accuracy of ±1°C.
This accuracy for the LM76CHM is specified for a −10°C to 45°C temperature range.
The LM76CHM is specified with an accuracy ±0.
5°C at 25°C.
The window-comparator architecture of the LM76 eases the design of temperature control systems conforming to the ACPI (Advanced Configuration and Power Interface) specification for personal computers.
The open-drain Interrupt (INT) output becomes active whenever temperature goes outside a programmable window, while a separate Critical Temperature Alarm (T_CRIT_A) output becomes active when the temperature exceeds a programmable critical limit.
The INT output can operate in either a comparator or event mode, while the T_CRIT_A output operates in comparator mode only.
The host can program both the upper and lower limits of the window as well as the critical temperature limit.
Programmable hysterisis as well as a fault queue are available to minimize false tripping.
Two pins (A0, A1) are available for address ...