DatasheetsPDF.com

MASW2000

Tyco
Part Number MASW2000
Manufacturer Tyco
Description GaAs SPDT Switch DC - 3 GHz
Published Apr 27, 2005
Detailed Description GaAs SPDT Switch DC - 3 GHz Features q q q q MASW2000 V 2.00 Low Insertion Loss, 0.5 dB Typical @ 2 GHz Fast Switching...
Datasheet PDF File MASW2000 PDF File

MASW2000
MASW2000


Overview
GaAs SPDT Switch DC - 3 GHz Features q q q q MASW2000 V 2.
00 Low Insertion Loss, 0.
5 dB Typical @ 2 GHz Fast Switching Speed, 22 ns Typical Reflective/Absorptive Configuration Ultra Low DC Power Consumption Guaranteed Specifications** (-55°C to +85°C) Frequency Range Insertion Loss DC–0.
5 GHz DC–1.
0 GHz DC–2.
0 GHz DC–3.
0 GHz Relective◊ Absorptive◊◊ Isolation DC–0.
5 GHz DC–1.
0 GHz DC–2.
0 GHz DC–3.
0 GHz DC–2.
0 GHz DC–3.
0 GHz DC–0.
5 GHz DC–1.
0 GHz DC–2.
0 GHz DC–3.
0 GHz DC - 3.
0 GHz 0.
5 dB Max 0.
6 dB Max 0.
8 dB Max 1.
0 dB Max 1.
20:1 Max 1.
20:1 Max 1.
20:1 Max 1.
40:1 Max 1.
20:1 Max 1.
40:1 Max 43 dB Min 35 dB Min 27 dB Min 24 dB Min 50 Ω Nominal 22 ns Typ 27 ns Typ 25 mV Typ 0/-8 +26 dBm Typ +32 dBm Typ Typical Performance @ +25°C*** VSWR Operating Characteristics Impedance Switching Characteristics tRISE, tFALL (10/90% or 90/10% RF) tON, tOFF (50% CTL to 90/10% RF) Transients (In-Band) Input Power for 1dB Compression Control Voltages (Vdc) 0/-5 0.
05 GHz +24 dBm 0.
5–3.
0 GHz +26 dBm Intermodulation Intercept Point (for two-tone input power up to +5 dBm) Intercept Points IP2 0.
05 GHz +63 0.
5–3.
0 GHz +80 IP3 +43 +53 dBm Typ dBm Typ Control Voltage (Complementary Logic) VINLow 0 to -0.
2 V @ 5 uA Max VINHi -5 V @ 60 uA Typ to -8 V @500 uA Max Die Size 0.
056" x 0.
056" x 0.
010" 1.
40mm x 1.
40mm x 0.
25mm) Schematic ** All specifications apply with 50 Ω impedance connected to all RF ports, 0 and 0 and -5 Vdc control voltages.
*** Loss changes 0.
0025 dB/°C (From -55°C to +85°C) ◊ For relective operation RL1/RL2 are unconnected.
◊◊ For absorptive operation RL1 connects to RF1 and RL2 connects to RF2.
Handling, Mounting, Bonding Procedure Handling Precautions Permanent damage to the MASW2000 may occur if the following precautions are not adhered to: A.
Cleanliness — The MASW2000 should be handled in a clean environment.
DO NOT attempt to clean unit after the MASW2000 is installed.
B.
Static Sensitivity — All chip handling equipment and personnel should be DC grounded.
C.
Tr...