Detailed Description Gas Tube Coaxial Surge Protector P8AX Series The P8AX series coaxial surge protectors have been designed to protect an...
Datasheet PDF File P8AX PDF File

P8AX
P8AX


Overview
Gas Tube Coaxial Surge Protector P8AX Series The P8AX series coaxial surge protectors have been designed to protect antennas, microwaves, broadband applications, two-way radios, cellular equipment and GPS equipment against lightning surges and electrical transients.
They are a first line of defense for your sensitive equipment.
The P8AX series employ a patented gas tube and are available with three grounding options, M6 ground screw, bulkhead or optional mounting bracket.
Applications • Tower Mounted Amplifiers (TMA) • Global Positioning Systems (GPS) • Antenna Systems • Tower Top Electronics (TTE) • Transmitters and Receivers • WiFi • Broadband Wireless Connector N BNC 0.
5Ghz <-25dB <0.
05dB <-25dB <0.
05dB 1Ghz <-25dB <0.
03dB <-25dB <0.
03dB 4Ghz <-20dB <-0.
29dB <-20dB <-0.
29dB High-Frequency Surge Protection • 20kA transient amps protection (8/20µs) • 5kA transient amps protection (10/350µs) • DC Pass to +/-48V • VSWR < 1.
2 • Insertion Loss < 0.
1dB • Bi-directional, series installed • Removable GDT Specifications Citel Model P8AX09 P8AX25 P8AX50 Max Power Insertion Loss Ipeak (8/20µs x 10) (100V/s) 70W < 0.
1dB 20kA 90-130V < 600V < 1.
2 50 Ohms DC-5GHz 500W < 0.
1dB 20kA 200-300V < 600V < 1.
2 50 Ohms DC-5GHz 1,000W < 0.
1dB 20kA 400-600V < 1000V < 1.
2 50 Ohms DC-5GHz Breakdown V Residual V VWSR Impedance (1kV/µs) Frequency Range Housing Material Relative Humidity Operating Temp.
Operating Altitude Copper Alloy with CuZnSn Finish 0 to 100% condensing -40°C to +80°C 13,000 ft (400m) Series GDT based TNC, BNC, N, 7/16, SMA, F M6 Screw, Bulkhead, Bracket 42Wx80L (in mm) Ordering information P8AX -___-_____(__ /__) Gender type Connection Method Max Power: 09 - 70W 25 - 500W 50 - 1kW Connector Type: N BNC TNC SMA 7/16 F *add W for bulkhead Protection Type Connectors Earthing Dimensions Citel, Inc.
1515 N.
W.
167th St, Suite 6-303 Miami, FL 33169 USA (800) 248-3548 ♦ Tel.
(305) 621-0022 ♦ Fax (305) 621-0766 www.
citelprotection.
com ♦ citel@citelprotection.
com Gas...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)