DatasheetsPDF.com

RE46C112

R & E International
Part Number RE46C112
Manufacturer R & E International
Description Ionization Smoke Detector IC
Published Mar 27, 2007
Detailed Description www.DataSheet4U.com R&E International RE46C112 Ionization Smoke Detector IC Product Specification General Description ...
Datasheet PDF File RE46C112 PDF File

RE46C112
RE46C112


Overview
www.
DataSheet4U.
com R&E International RE46C112 Ionization Smoke Detector IC Product Specification General Description The RE46C112 is an ionization type smoke detector IC.
It is intended for applications using ionization type chambers to detect smoke.
When enabled, VOUT is ¼ of either the DETECT input or VDD depending on the status of the SELECT input.
When the Select input is allowed to float the circuit is in the low current mode with only the guard amplifier enabled.
Utilizing low power CMOS technology the RE46C112 was designed for use in smoke detectors that comply with Underwriters Laboratory Specification UL217.
Features • • • • • • • Guard Outputs for Ion Detector Input ± 0.
75pA Detect Input Current Microprocessor A/D Compatible Analog Output Low Quiescent Current Consumption (<10uA) Available in 8L PDIP or 8L N SOIC 2000V ESD Protection (HBM) Available in Standard Packaging or RoHS Compliant Pb Free Packaging Pin Configuration 1 8 G2 DETECT G1 VO UT VDD VCC SELECT VSS ABSOLUTE MAXIMUM RATINGS PARAMETER Supply Voltage Supply Voltage Detect Input Voltage Range SELECT Input Voltage Range Operating Temperature Storage Temperature Maximum Junction Temperature SYMBOL VDD VCC VINDET VINSEL TA TSTG TJ VALUE 12.
5 6 VDD +.
3 VCC +.
3 -10 to 60 -55 to 125 150 UNITS V V V V °C °C °C Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device.
These are stress ratings only and operation at these conditions for extended periods may affect device reliability.
This product utilizes CMOS technology with static protection; however proper ESD prevention procedures should be used when handling this product.
Damage can occur when exposed to extremely high static electrical charge Telephone 610.
992.
0727 Page 1 of 5 E-mail: rande@randeint.
com DS-RE46C112-011207 This datasheet contains PROPRIETARY and CONFIDENTIAL information.
Facsimile 610.
992.
0734 RE46C112 Ionization Smoke Detector IC Product Specification R&E International Elect...