Description 10...30 Watt AC-DC Converters
Published Mar 22, 2005
Detailed Description LHR, LGR 4/5000 Series 10...30 Watt AC-DC Converters Input voltage ranges 85...265 V AC 88…168 V DC 1 or 2 outputs up t...
Datasheet PDF File LHR5020-2 PDF File

LHR5020-2
LHR5020-2


Overview
LHR, LGR 4/5000 Series 10.
.
.
30 Watt AC-DC Converters Input voltage ranges 85.
.
.
265 V AC 88…168 V DC 1 or 2 outputs up to 48 V DC 4300 V DC I/O electric strength test voltage LGA • Class II equipment (double insulation) • Short circuit protection • Compact, low cost solution Selection chart Output 1 Uo nom Io nom [V DC] [A] 3.
3 3 3.
3 7 5 2 5 5 12 1.
2 12 2.
5 15 1 15 2 24 0.
6 24 1.
25 3.
3 1.
5 3.
3 2.
5 +5 1.
25 +5 2.
5 +5 1 +5 2.
5 +12 0.
6 +12 1.
25 +15 0.
5 +15 1.
0 +24 0.
3 +24 0.
625 Output 2 Uo nom Io nom [V DC] [A] +5 1 +5 2.
5 -5 1.
25 -5 2.
5 +12 0.
5 +12 1.
25 -12 0.
6 -12 1.
25 -15 0.
5 -15 1.
0 -24 0.
3 -24 0.
625 Input voltage Ui Rated power TA = 50 °C Po tot [W] 10 23 10 25 14.
4 30 15 30 14.
4 30 10 20.
8 12.
5 25 11 27.
5 14.
4 30 15 30 15 30 Type 85…264 V AC (47…63 Hz) 88…168 V DC LHR 4101-2 LGR 4101-2 LHR 4001-2 LGR 4001-2 LHR 4301-2 LGR 4301-2 LHR 4501-2 LGR 4501-2 LHR 4601-2 LGR 4601-2 LHR 5101-2 LGR 5101-2 LHR 5001-2 LGR 5001-2 LHR 5020-2 LGR 5020-2 LHR 5320-2 LGR 5320-2 LHR 5540-2 LGR 5540-2 LHR 5660-2 LGR 5660-2 www.
power-one.
com Edition 5/07.
2001 1 Board Mountable Input Input voltage Input frequency continuous range LHR, LGR 4/5000 Series 85.
.
.
264 V AC / 88…168 V DC 47.
.
.
63 Hz Output Efficiency Output voltage switching noise Line and load regulation Uo1 Line and load regulation Uo2 Minimum load Hold-up time 230 V AC, Io nom Ui nom, Io nom, 20 MHz bandwidth, peak-peak Ui min…Ui max, (10…100%) • Io nom Ui min…Ui max, (10…100%) • Io nom not required on single output types recommended 0.
1 Io nom on double output types 110/230 V AC, Io nom up to 86% <1% ±1% ±2% >10 ms Protection Output overload Short circuit No load hiccup mode on LHR types / rectangular on LGR types Control Trim /R ±80…110% Uo nom Safety and EMC Safety marks Electric strength test voltage Electrostatic discharge Electromagnetic field Electr.
fast transients/burst Surge Electromagnetic emissions 900 MHz Test UL, ULc, CE I/O IEC/EN 61000-4-2, level 4 (15 kV) IEC/EN 61000-4-3, level 3 (10 V/m) IEC/EN ...