DatasheetsPDF.com

ALQ25B50N-AL

Emerson
Part Number ALQ25B50N-AL
Manufacturer Emerson
Description DC-DC / Industry Standard Isolated Quarter Brick
Published Oct 25, 2009
Detailed Description Astec Industry Standard 300 Watts ALQ25B50 DC Transfromer Total Power: Input Voltages: No. of Outputs: 300W (12V @ 25...
Datasheet PDF File ALQ25B50N-AL PDF File

ALQ25B50N-AL
ALQ25B50N-AL


Overview
Astec Industry Standard 300 Watts ALQ25B50 DC Transfromer Total Power: Input Voltages: No.
of Outputs: 300W (12V @ 25A) 48V Single Electrical Specs Input Input Range1 Efficiency Over Voltage Protection Input UVLO1 42 to 53 VDC 96%@12V (Typ) 60V 39V to 42V Output Output Current Line Regulation Load Regulation Noise/Ripple2 Transient Response 0A to 25A max (300W output power) 10.
25V to 13.
60V 8.
50V to 13.
60V (for “-AL” option) ±3% Vo (Typical) 100mV (Typical) 200mV typical deviation 50% to 75% Load Change 100µs max recovery time 115% IO,MAX typical (latching) 800kHz Special Features • High efficiency (96% Typical) • -40°C to +100°C Ambient Air Operation • Industry standard package Qtr Brick 1.
48" x 2.
30" x 0.
40" • High capacitive load limit on start-up • 12V @ 25A Intermediate Bus Voltage for DPA application • Regulation to zero load • Output Enable Pin • Meets Basic Insulation • Input UVLO and Overvoltage Protection • Over Temperature Protection Over Current Limit1 Switching Frequency Control Enable TTL compatible (Positive or Negative Enable Logic) Isolation Voltage Input to Output 2000Vdc max Environmental Ambient air operating temperature range: -40°C to +100°C Storage temperature: -55°C to +125°C Overtemperature protection: 115°C typical MTBF: > 1 million hours * Specifications are subject to change without notice.
Safety UL, cUL 60950 TUV EN60950 1 North America (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211Asia (HK): 852-2437-9662 AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 ALQ25B50 Ordering Information Input Voltage 42V 42V 42V 42V 36V to to to to to 53V 53V 53V 53V 53V Output Voltage ...



Similar Datasheet


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site. (Privacy Policy & Contact)