DatasheetsPDF.com

HPS15Y-NNR-000

Emerson
Part Number HPS15Y-NNR-000
Manufacturer Emerson
Description AC-DC / Distributed Power Front End 3U
Published Oct 25, 2009
Detailed Description 1000-6000 Watts HPS10/12/15 Series Electrical Specs Input Input voltage Frequency Inrush current Efficiency Power factor...
Datasheet PDF File HPS15Y-NNR-000 PDF File

HPS15Y-NNR-000
HPS15Y-NNR-000


Overview
1000-6000 Watts HPS10/12/15 Series Electrical Specs Input Input voltage Frequency Inrush current Efficiency Power factor Turn-on time 85-264 VAC* 47-440 Hz 40 A peak max.
85% typ @ full case load 230 VAC 0.
99 typical meets EN61000-3-2 AC on 1.
5 sec.
typical, Inhibit / Enable 100 ms typical CISPR 22 EN55022 Level “B” 2 mA max @ 264 VAC @ 60Hz (per module) CISPR 22 EN55022 Level “B” 20 ms minimum (independent of input VAC) >5 ms early warning min.
before outputs lose regulation; Full cycle ride thru (50 Hz) Meets EN61000-3-2 Meets EN60950 Special Features • • • • • • • • • • • • • • • • • • • • • • • • • • Integrated OR-ing diode Remote Sense on Bulk output Overload protection on all outputs Active Inrush limiting PFC to 0.
99 typical EN61000-3-2 CISPR22, EN55022 Curve B conducted/radiated EMI EN61000 immunity standards Optional 48 W fan voltage (12 V or 24 V) Standard 5 V at 5 A standby voltage (3.
3V option) No minimum load Overvoltage protection Input OK signal and indicator LED Inhibit/Enable Remote Margin/Voltage Programming Optional current monitor Optional AC Line discrimination Output Good signal and indicator LED Temp good signal and indicator LED Optional single wire digital temp monitor 2 Optional module I C interface Optional Rack µController Hot Plug N+1 Redundant Standard Optional fan fail signal Module present signal Optional short circut latch EMI filter standard Leakage current standard Radiated EMI Holdup time AC OK Harmonic distortion Isolation * see modules table on the next page Output Margining Overall reg Ripple Dynamic response Recovery time Overcurrent protection Short circuit protection Overvoltage protection Reverse voltage protection Thermal protection Remote sense Single wire parallel DC OK Minimum load Standby voltage Global Inhibit/Enable ±5% of nominal 1% 1% of Vout Pk-Pk limited to 20 MHz 2% with 25% load step To within 1% in <300 µsec 105-120% of rated output current Protected for continuous short circuit.
Recovery is automatic upon...