DatasheetsPDF.com

LGEF930A1

Luguang Electronic
Part Number LGEF930A1
Manufacturer Luguang Electronic
Description SAW Filter
Published Nov 23, 2013
Detailed Description LGE F930A1 SAW Filter 1. SCOPE This specification shall cover the characteristics of SAW filter With F930A1 used for th...
Datasheet PDF File LGEF930A1 PDF File

LGEF930A1
LGEF930A1


Overview
LGE F930A1 SAW Filter 1.
SCOPE This specification shall cover the characteristics of SAW filter With F930A1 used for the page system.
2.
ELECTRICAL SPECIFICATION DC Voltage VDC AC Voltage Vpp Operation temperature Storage temperature RF Power Dissipation Electronic Characteristics 2-1.
Typical frequency response 0V 10V50Hz/60Hz -20℃ to +60℃ -45℃ to +85℃ 0dBm 2-2.
Electrical characteristics Part Number Nominal center frequency(MHz) Insertion loss(dB) 1.
Fo±2.
0MHz 2.
Fo-400.
0~-40.
8MHz 3.
Fo+50.
0~+400MHz Ripple deviation (Fo±2.
0MHz) Input/output impedance (Nominal) LGEF930A1 930.
5 4.
5 max.
45 min.
45 min.
2.
0 max.
50+j52.
8 ohm SHENZHEN LUGUANG ELECTRONIC TECHNOLOGY CO.
,LTD.
Free Datasheet http://www.
datasheet4u.
com/ LGEF930A1 SAW Filter 3.
TEST CIRCUIT 4.
DIMENSION 5.
ENVIRONMENTAL CHARACTERISTICS 5-1 High temperature exposure Subject the filter to +80℃ for 96 hours.
Then release the filter into the room conditions for 1 to 2 hours prior to the measurement.
It shall fulfill the specifications in table 1.
5-2 Moisture Keep the filter at 40℃ and 95% rh for 96 hours.
then release the filter into the room conditions for 1 to 2 hours prior to the measurement.
It shall fulfill the specifications in table 1.
SHENZHEN LUGUANG ELECTRONIC TECHNOLOGY CO.
,LTD.
Free Datasheet http://www.
datasheet4u.
com/ HDF930A1 SAW Filter 5-3 Low temperature exposure Subject the filter to -20℃ for 96 hours.
Then release the filter into the room conditions for 1 to 2 hours prior to the measurement.
It shall fulfill the specifications in table 1.
5-4 Temperature cycling Subject the filter to a low temperature of -55℃for 30 minutes.
Following by a high temperature of +85℃ for 30 Minutes.
Then release the filter into the room conditions for 1 to 2 hours prior to the measurement.
It shall meet the specifications in table 1.
5-5 Resistance to solder heat Dip the filter terminals no closer than 1.
5mm into the solder bath at 270℃ ±10℃ for 10±1 sec.
Then release the Filter into the room condition...