Part Number
|
LM1851 |
Manufacturer
|
National Semiconductor |
Description
|
Ground Fault Interrupter |
Published
|
Mar 22, 2005 |
Detailed Description
|
com
LM1851 Ground Fault Interrupter
June 1992
LM1851 Ground Fault Interrupter
General Description
The...
|
Datasheet
|
LM1851
|
Overview
com
LM1851 Ground Fault Interrupter
June 1992
LM1851 Ground Fault Interrupter
General Description
The LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environments Ground fault currents greater than a presettable threshold value will trigger an external SCR-driven circuit breaker to interrupt the AC line and remove the fault condition In addition to detection of conventional hot wire to ground faults the neutral fault condition is also detected Full advantage of the U S UL943 timing specification is taken to insure maximum immunity to false triggering due to line noise Special features include circuitry that rapidly rese...