DatasheetsPDF.com

TH505

Panasonic
Part Number TH505
Manufacturer Panasonic
Description HOUR METER
Published Jun 14, 2016
Detailed Description DIN48 MINUTES INDICATOR HOUR METER TH50 Hour Meters 80.5 3.169 48 1.890 48 1.890 Silver panel mm inch Black panel ...
Datasheet PDF File TH505 PDF File

TH505
TH505


Overview
DIN48 MINUTES INDICATOR HOUR METER TH50 Hour Meters 80.
5 3.
169 48 1.
890 48 1.
890 Silver panel mm inch Black panel RoHS Directive compatibility information http://www.
nais-e.
com/ Features 1.
Measurement and management in units of minutes Unlike conventional hour meters, the time can be measured and managed in minutes.
2.
Reset button The hour meters can be reset to zero for repeated measurement.
3.
High-performance compact syncronous motor The accurately turning motor is employed to provide for longer period of measurement.
4.
Common for 50/60 Hz power frequency A lever is used to select 50 Hz or 60 Hz.
There is no need to rearrange the control panel and other signal destinations.
5.
Dimensions as per DIN 43700 standard The units are in the 48 × 48 DIN standard size.
They can be fitted in panels and give refined metallic appearance.
6.
Easier wiring The flat terminals (#187) are quick and easy to connect.
7.
Rotary indicator The rotary indicator makes one turn every 2 seconds for monitoring.
8.
Compliant with CE.
Specifications Rated operating voltage Allowable operating voltage range Rated frequency Counting range Minimum time display Rated power consumption Insulation resistance (Initial value) Breakdown voltage (Initial value) Max.
temperature rise Vibration resistance Functional Shock resistance Functional Destructive Ambient temperature Ambient humidity Weight 12 V AC, 24 V AC, 48 V AC, 100 V AC, 110 V AC, 115 to 120 V AC, 200 V AC, 220 V AC, 240 V AC 85 to 115% of rated operating voltage 50/60 Hz (selectable by switch) 0 to 9999.
9 min 0.
1 min (6 sec) Approx.
1.
5 W Min.
100 MΩ, Between live and dead metal parts (At 500 V DC) 2,000 Vrms, Between live and dead metal parts 55°C 131°F 10 to 55 Hz: 1 cycle/min double amplitude of 0.
5 mm (10 min on 3 axes) Min.
98 m/s2 {10 G} (4 times on 3 axes) Min.
980 m/s2 {100 G} (5 times on 3 axes) –10 to +50°C +14 to +122°F Max.
85% RH (non-condensing) 150 g 5.
29 oz Product types Type TH50 series Oper...